Error messages
73
Service-instructions
Disconnect CAN bus cable between control board
and motor. Then restart the device. Does the error
still appear?
Disconnect the communication line between the
operating unit and the control board. Check whether
the fault still appears.
Replace operating unit
Replace control board
Replace communication line. Check whether the fault
still appears.
Replace CAN bus cable. Check whether the fault still
appears.
No
No
Yes
Yes
Yes
Replace motor.
Yes
Troubleshooting takes place by disconnecting individual CAN bus connections. Other error
messages are generated in the process. The decisive factor is that the original message "5009 or
5010" is no longer displayed.
Restore software with USB backup tool