6.8 DynaSteam test
Description
The DynaSteam test allows the function test of the DynaSteam
steaming unit.
Calibration of the steaming unit is not possible / necessary.
Prerequisite
Access to the water supply pipe in the cooking chamber.
Remove both hook-in points.
Dismount water supply pipe.
Dismount air diverter.
Replace water supply pipe.
Overview
Starting the test
Touch "Initialization" field.
Automatic pre-rinse.
Field changes to "START".
Set water quantity using the rollers.
Touch the "START" field.
Activation of the DynaSteam steaming unit.
The water comes runs from the water supply pipe into the
cooking chamber.
Check the water quantity
Collect the water from the supply pipe with a measuring container.
Starting water test.
After the predetermined amount of water has gone through, the
steaming unit stops automatically.
Compare amount of water with the set value. A deviation of +-
10% is within tolerance.