Service menu - appliance test
19
Service-instructions
Step 8 (WaveClean siphon pump)
1. Check of WaveClean siphon pump.
Display switches to green = test successful.
Display switches to red = test not successful.
Check of siphon pump via relay test. A fault is present on the
component or the control board. Check the fuse on the control
board.
Step 9 (temperature control)
1. Check of temperature control.
The temperature in the cooking chamber must reach within the
time specified.
Display switches to green = test successful.
Display switches to red = test not successful.
Check region around cooking chamber sensor for soiling.
Check temperatures via calibration in the service menu.
If necessary, replace cooking chamber sensor or control board.