Service menu - appliance test
17
Service-instructions
Status 4
Miscellaneous
K3: Manual rinse
K10: Activation of the exhaust hood at high speed (option)
B15: Reed contact switch
K07, K13, K14: Not used
Temperature sensors B1, B3, B6, B7 are not present.
6.4 CombiDoctor
Description
The CombiDoctor offers an automatic check of the climate control
and the WaveClean automatic cleaning. The tests are possible
individually or as overall test. For instructions on performing, see the
touchscreen.
Overview
Selecting a program
Select a program by adjusting the roller.
Starting the program
Touch the "START" field.
Evaluation
The test result appears on the touchscreen.
Entry in HACCP memory.
Description of the test
steps
Step 1 (test door contact)
1. Open cooking chamber door and close again.
If test successful, proceed with the next test step.
If the door is not recognized as having been opened and
closed again within the specified time (60 seconds), the test is
not passed.
Step 2 (prepare for WaveClean)
1. Preparation for WaveClean test.
Automatic water exchange via the siphon pump and the solenoid
valve for steam elimination.
3727002-0B-AE-12/15/2022
Summary of Contents for FlexFusion ELECTRIC SPACESAVER FSE-610
Page 6: ...Directory of contents 6 Service instructions 3727002 0B AE 12 15 2022...
Page 49: ...Software 49 Service instructions Exiting selection Tap the Back field 3727002 0B AE 12 15 2022...
Page 52: ...Electronics 52 Service instructions 10 2 Control board 10 2 1 Layout 3727002 0B AE 12 15 2022...
Page 76: ...Error messages 76 Service instructions 3727002 0B AE 12 15 2022...
Page 77: ......
Page 78: ......
Page 79: ......