Error messages
58
Service-instructions
Is the wire or the test prod damaged physically?
Remove existing core temperature sensor from the control board A1, X24 and
plug in new core temperature sensor. Error eliminated?
Replace control board.
Replace core temperature sensor.
No
Yes
11.4 Water vapor sensor defective (710)
Description
In the event of an error, emergency operation is activated and
displayed automatically. The software controls steam elimination. In
this case, increased water consumption may result.
Troubleshooting
Check contacting from cooking chamber sensor to control board A1 X27. Error eliminated?
Remove connector of existing vapor sensor from control board A1 X27 and plug in new vapor
sensor. Error eliminated?
Replace control board.
Replace vapor sensor.
No
Yes
3727002-0B-AE-12/15/2022
Summary of Contents for FlexFusion ELECTRIC SPACESAVER FSE-610
Page 6: ...Directory of contents 6 Service instructions 3727002 0B AE 12 15 2022...
Page 49: ...Software 49 Service instructions Exiting selection Tap the Back field 3727002 0B AE 12 15 2022...
Page 52: ...Electronics 52 Service instructions 10 2 Control board 10 2 1 Layout 3727002 0B AE 12 15 2022...
Page 76: ...Error messages 76 Service instructions 3727002 0B AE 12 15 2022...
Page 77: ......
Page 78: ......