In the event of a control system failure, the digital display shows an error message.
The message codes are shown in the display column below. A constant tone is heard
when an error code is displayed, and to silence this tone, press any button.
T
Ta
ab
blle
e 1
1--2
2 E
Errrro
orr C
Co
od
de
ess
Display
Cause
Panel Board Correction
“E-4”
Control board
overheating.
Turn switch to off position, then turn switch back to on; if
display shows “E-4”, the control board is getting too hot;
check the louvers on each side of the unit for obstruction.
“E-5”
Oil overheating.
Turn switch to off position, then back to on; if display
shows “E-5”, the heating circuits and temperature probe
should be checked.
“E-6A”
Temperature
probe open.
Turn switch to off position, then turn switch back to on; if
display shows “E-6A”, the temperature probe should be
checked.
“E-6B”
Temperature
probe shorted.
Turn switch to off position, then turn switch back to on; if
display shows “E-6B”, the temperature probe should be
checked.
“E-10”
High limit.
Let unit cool down (15-20 minutes), push up on metal re-
set button under right side of the controls; if high limit does
not reset, high limit must be replaced.
“E-15”
Drain switch.
Make sure drain knob is completely pushed-in; if “E-15”
persists, have drain switch checked.
“E-18-A”
Left level sensor
open.
Turn switch to off position, then back to on; if display still
indicates a failed sensor, have the connections checked
on the control board. Have sensor checked and replaced
if necessary.
“E-18-B”
Right level sen-
sor open.
“E-18-C”
Both level sen-
sors open.
“E-20-A”
“FAN SEN-
SOR
STUCK
CLOSED”
Pressure switch
failure.
If fan is not running, have pressure switch checked;
should be open circuit if no air pressure.
Wiring problem.
If fan is running, wiring error, or relay on I/O board closed.
I/O board failure.
“E-20-B”
“NO
DRAFT”
“CHECK
FAN”
Pressure switch
failure/hose
loose.
Press power button to vat off and back on again, if E-20-B
persists, have pressure switch checked; should be open
circuit if no air pressure; make sure hose is connected to
fan and pressure switch.
Draft fan failure/
low voltage.
Have draft fan checked; low voltage going to fan.