64
General
11) Technical Data
Working place specific noise level: <70dB
Average water consumption during operation:
Model 6:
3.17 gal/hr (0.2 l/min.)
Model 10:
6.7 gal/hr (0.42 l/min.)
Model 1020:
10.9 gal/hr (.069 l/min.)
Model 20:
13.2 gal/hr (0.83 l/min.)
Model 40:
15.8 gal/hr (1.0 l/min.)
Heat emission:
INSTALLATION
Model
Latent
Sensible
LCS/G-6
.64 W (2.30 kJ)/hr
84 W (2.93 kJ)/hr
LCS-G-10
1.05 W (8.50 kJ)/hr
1.4 W (5.00 kJ)/hr
LCS/G-1020
1.67 W (6.00 kJ)/hr
2.4 W (8.50 kJ)/hr
LCS-G-20
2.13 W (7.67 kJ)/hr
2.67 W (9.60 kJ)/hr
LCS/G-40
3.7 W (13.35 kJ)/hr
4.26 W (15.34 kJ)/hr
Ventilation
Contact your local regulatory agency for ventilation requirements. If a ventilation
hood is installed, observe the following:
■
The standards of the local authority.
■
The hood should protrude 12-20 in. (300-500 mm) over the front of the
appliance.
■
The integrated grease filter should be in the protruding part of the hood.
Specifications and technical descriptions in this applications manual are subject to
change without prior notice.
Gas supply
12) Gas supply (for LCG units only)
The ClimaPlus gas model is available for either natural or propane gas. Check
the data plate on the left corner of the unit to determine the proper gas supply
requirement.
Model
Gas Line
Connection
LCG-6
3
⁄
4
in.
1
⁄
2
in.
LCG-10
3
⁄
4
in.
3
⁄
4
in.
LCG-1020
1 in.
3
⁄
4
in.
LCG-20
1 in.
3
⁄
4
in.
LCG-40
1
1
⁄
4
in.
1 in.