38
PROG
START
PROG
START
+DELTA-T
Operation and settings
■
Turn unit on.
■
Load oven rack.
■
Insert IQT Sensor probe.
■
DO NOT select cooking mode. Deactivate if mode has already been selected.
■
Press IQT key: (“+PROFILE” appears in the adjacent display.) Use Central Dial
to DELTA-T.
■
Press PROG/START key to activate program. Pre-selected settings will appear
on the TEMPERATURE and IQT Sensor displays.
■
Press TEMPERATURE key and use Central Dial to enter desired Delta
temperature–68-140°F (20-60°C).
■
Press IQT Sensor key and use Central Dial to enter desired core
temperature–110-210°F (45-99°C).
■
Press PROG/START to confirm and inDelta-T cooking.
During operation
■
Since +Delta-T cooking operates in Moist Heat mode, the ClimaPlus window
will display a blue bar and the Moist Heat mode key will be active during the
cooking cycle.
■
The actual core temperature will appear in the display next to “done” core
temperature.
■
The control panel is not accessible during operation except for the following
functions (may depend on model.)
•
IQT, HACCP (all LCS and LCG models)
•
Half Energy (all LCS Electric models)
•
Half Fan Speed (all LCS Electric models and the LCG-40 Gas)
■
Opening the door during operation merely interrupts the cooking process.
When door is closed, all functions resume.
■
To stop the IQT +Delta-T program altogether, it is necessary to turn off the unit.
NOTE:
For a Delta-T Cooking program without IQT Logic see “Special Functions:
Delta-T Cooking”, page 40.
COOKING
FUNCTIONS
IQT +DELTA-T
COOKING
continued