background image

DP14

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

DANGER

TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK,

CAREFULLY FOLLOW THESE INSTRUCTIONS

TABLE OF CONTENTS

SECTION «A»DESCRIPTION

     

PAGE

Installation and maintenance manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A1

Construction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A2

Shipping . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A2
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A3

Distances to respect . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A4
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A4

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A5

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 A6

Maintenance and cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  A7
For more information, please contact our office: . . . . . . . . . . . . . . . . . . . .  A8

SECTION «B» DIMENSIONS
DP14 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

SECTION «E» COMPONENT PARTS
Component parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 B1

 E1

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

DP14.DOC

 Rev. 

01.2008

Summary of Contents for DP14

Page 1: ...NTS SECTION A DESCRIPTION PAGE Installation and maintenance manual A1 Construction A2 Shipping A2 Warnings A3 Distances to respect A4 Installation A4 Operation A5 Troubleshooting A6 Maintenance and cleaning A7 For more information please contact our office A8 SECTION B DIMENSIONS DP14 SECTION E COMPONENT PARTS Component parts B1 E1 Warranty DP14 DOC Rev 01 2008 ...

Page 2: ...cifies the serial number model number number of phase amperage voltage and frequency Drawings electrical diagram and replacement part numbers are included in this manual The electrical diagram is affixed in the control panel located on the top of the proofer ATTENTION DOYON is not responsible for damages to the property or the equipment caused by personnel who is not certified by known organizatio...

Page 3: ...efore shipment The freight company assumes full responsibility concerning the delivery in good condition of the equipment in accepting to transport it IMPORTANT RECEPTION OF THE MERCHANDISE Take care to verify that the received equipment is not damaged before signing the delivery receipt If a damage or a lost part is noticed write it clearly on the receipt If it is noticed after carrier left conta...

Page 4: ...ce must be done by specialized technicians Contact a certified electrician and plumber for set up The proofer must be connected to the utility and electrically grounded in conformity to the effective local regulations If these are not established the oven must be connected according to the Canadian Electrical Code CSA C22 1 XX or National Electrical Code NFPA 70 XX Refer to last edition year for X...

Page 5: ...the wheels after installation and use a flexible conduit 1 To the electrician Electrical supply installation must be in accordance with the electrical rating on the nameplate and use flexible wire 2 To the plumber MANUAL WATER FILL No water line is required Water is filled manually in the pan inside the proofer This equipment is to be installed to comply with the applicable federal state or local ...

Page 6: ...ide until they are ready to bake 5 When proofing cycle is completed turn the switch OFF When the proofer is not in operation open the doors to let out the humidity and then prevent mould P S The doors should not be opened unnecessarily to conserve the heat and humidity in the proofer Every day cleaning of the water pan under the proofer s doors should be exercised POWER FAILURE When the power come...

Page 7: ...s Solutions The unit does not turn on when installed Check if the light is on Check if the proofer switch is on Check the breaker of the building Check the fuses on the front and in the electrical control panel The blower runs but the unit does not produce heat Make sure that the thermostat is adjusted to the desired temperature over ambient temperature and the pilot light is lit The blower runs b...

Page 8: ...nit with water and soap We recommend and sell Dirt Buster III Action foam cleaner CHEMCO Part number NEB201 Clean the unit exterior with a stainless steel polish We recommend and sell Stainless steel cleaner SANY or CURTIS comestible Part number NES201 CAUTION Save these instructions ...

Page 9: ...ON PLEASE CONTACT OUR OFFICE DOYON EQUIPMENT INC 1255 rue Principale Linière Qc Canada G0M 1J0 Tel 1 418 685 3431 Canada 1 800 463 1636 U S 1 800 463 4273 FAX 1 418 685 3948 Internet www doyon qc ca E Mail doyon doyon qc ca ...

Page 10: ...SECTION B DIMENSIONS ...

Page 11: ...B1 ...

Page 12: ...B2 ...

Page 13: ...SECTION E COMPONENT PARTS ...

Page 14: ...E1 ...

Page 15: ...LI550 MAIN SWITCH SELECTOR 1 AND ELI555 CONTACT BLOCK 1NO 1 AND ELI556 ON OFF PLATE 1 5 ELB096 5A BREAKER 1 6 QUP465 DOOR HANDLE STAINLESS TUBING 2 7 VT1251 TEMPERED GLASS 5 MM 12 X 51 3 4 2 AND MBAV1921 ALUMINIUM DOOR EXTRUSION 2 8 QUP320 DOOR HINGE 4 9 QUA200 DOOR MAGNET 2 10 STP500 STAINLESS STEEL WATER PAN FOR BOTTOM DOOR 1 11 REEF10 STAINLESS STEEL WATER PAN 1 12 ELE185 ELEMENT CIRCULAR 120V ...

Page 16: ...E3 ...

Page 17: ...ription Quantity 1 ELM731 MOTOR BLOWER 115 CFM 1 2 ELE130 COIL ELEMENT 120V 1500W 1 3 ELB072 TERMINAL BLOCK 3P 175A 1 4 ELL050 GROUND LUG 1 5 ELC860 CONTACTOR 2P 30A 110V 1 6 ELT505 HIGH LIMIT TEMPERATURE 300 1 Model DP14 View ...

Page 18: ...ble for having the equipment properly installed operated under normal conditions with proper supervision and to perform periodic preventive maintenance If any parts are proven defective during the period of one year from date of purchase Doyon Equipment Inc hereby guarantees to replace without charge F O B Linière Quebec Canada such part or parts Doyon Equipment Inc will pay the reasonable labor c...

Reviews: