Henny Penny
Chick-fil-A Controls
Press and the next latest power-up date is shown. Up
to 10 power-ups (2B to 2K) can be stored in the P-LOG section.
Press to continue onto the heat-up log.
3. HEAT-UP’S
Press and
“3A. (date & time) *NOW*
shows in display. This
is the present date and time.
Press and the latest heat-up is shown, along with the heat-up rate,
ex:
“3B. MAY-22, 8:37A 1.25”
. The heat rate is the maximum rate
(degrees/second) the controller recorded during the shown time frame.
Press and the next latest heat-up is shown. Up to 10 heat-ups
(3B to 3K) can be stored in the HEAT-UP log.
Press to continue onto the COOK DATA.
4. COOK DATA
Press to step through the following data:
FUNCTION
DISPLAY EXAMPLE
Time of day the last cook cycle was started
4A. STARTED 10.25A
Product (Last product cooked)
4B. PRODUCT -1-
Ready? (Was fryer Ready before start?)
4C. READY? YES
Drop Detect Status
4D. DETECT
\
/ T-14
Drop Adjust (real time seconds)
4E. DROP ADJ T-14
Cook Time Adj (clock adjust)
4F. CK TM ADJ -13
Actual Elapsed Cook Time (real seconds)
4G. ACT TIME 4:50
Stopped: Time remaining, or secs past Done
4H. STOP DONE+2
“Slow Cook” for this cycle?
4I. SLOW? NO
Frozen or Overload? (Bad batch)
4J. FRZ/OVL? NO
Avg Temp during cook cycle
4K. AVG TMP 317°F
Max Voltage during cook cycle
4L. MAX VOLT 99%
Min Voltage during cook cycle
4M. MIN VOLT 97%
Max Amps during cook cycle
4N. MAX AMPS 35
Min Amps during cook cycle
4O. MIN AMPS 34
Press to continue onto TODAY’S DATA.
3-4. INFORMATION MODE
DETAILS
602
3-27