Henny Penny
Chick-fil-A Controls
Problem
Cause
Correction
POWER SECTION
With Cook/Pump Switch in
• Open Circuit.
• Check to see if fryer is plugged
Cook position, fryer is
in.
completely without power
•
Check wall circuit breaker or
fuse.
•
Have a qualified service techni-
cian check power supply and
Cook/Pump switch.
PRESSURE SECTION
Pressure will not
•
Exhaust line from solenoid
•
Turn unit off and allow fryer to
exhaust at end of
valve to exhaust tank
cool to release pressure from
cooking cycle.
clogged.
frypot; have all pressure lines,
exhaust stacks, and exhaust
tank cleaned.
•
Solenoid valve clogged.
•
Have solenoid checked and
cleaned.
Operating pressure too high
•
Dead weight clogged.
•
Turn unit off and allow fryer to
cool to release pressure from
frypot; remove dead weight and
clean, per section 3-16.
DO NOT OPERATE
•
Exhaust line to stack clogged.
•
Clean exhaust line to stack.
UNIT IF HIGH PRES-
SURE CONDITIONS
EXIST, SEVERE
INJURIES AND BURNS
WILL RESULT. PLACE
THE COOK/PUMP
SWITCH IN THE “OFF”
POSITION IMMEDI-
ATELY. RELEASE THE
PRESSURE BY ALLOW-
ING UNIT TO COOL.
THE PRESSURE WILL
THEN DROP. DO
NOT RESUME USE OF
UNIT UNTIL CAUSE OF
HIGH PRESSURE HAS
BEEN FOUND AND
CORRECTED.
3-6
602
PRESSURIZED