3-4. INFORMATION MODE
DETAILS
6. PREV DAY - SUN
Press to step through the following data. During each step, press
to choose the day of the week, of the past 7 days.
FUNCTION
DISPLAY EX:
Day this data was recorded for
6A. DATE APR-8
Time of day last heat-up was completed
6B. LAST HEAT 8:15P
Peak heat-up rate (°F/Sec) for last heat-up
6C. LAST RATE 0.88
Was that day’s last heat-up acceptable?
6D. LAST OK? YES
Heat Cap. status (based on last 4 ht-ups)
6E. HEAT CAP GOOD
Number of monitored heat-ups that day
6F. HEAT-UPS 7
Number of slow heat-ups
6G. SLOW HT’S 0
Max time to heat 270°F to 310°F that day
6H. MAX HT TM 1:11
Lowest “peak rate” for that day’s heat-ups
6I. MIN RATE 0.67
Maximum voltage that day (when fryer on)
6J. MAX VOLT 102%
Minimum voltage that day (when fryer on)
6K. MIN VOLT 98%
No. of “Low Voltage” warnings generated
6L. LO VOLT’S 0
Maximum Amp Draw that day
6M. MAX AMPS 35
Minimum Amp Draw that day
6N. MIN AMPS 34
No. of “Low Amps” warnings that day
6O. LO AMP’S 0
Non-cooking time (hh:mm) while fryer was on
6P. IDLE HRS 7:09
Oil Wear accumulated that day
6Q. OIL WEAR 39
Total number of cook cycles that day
6R. TOT CK’S 18
Number of cycles started before Ready
6S. NOT RDY’S 2
No. cycles quit early, (0:11 or more remaining)
6T. QUIT 11+ 1
No. cycles beeped *DONE* 21 sec or more
6U. DONE 21+ 3
Individual product cook counts
6V. Px CK CT 12
Individual product “not detected” counts
6W. Px NO DET 1
Individual product “slow cook” counts
6X. Px SLO CT 0
Individual product “frozen or overloaded”
6Y. Px FRZ/OV 1
During steps 6V through 6Y, press the product buttons (or
Manual Prog) to see data on individual product items.
Press to continue onto 7-DAY TOTALS log.
602