7.D Installation of Sensors LSM-BELT
Place the sensor onto the belt and close the strap at the side. Make sure that the belt is
positioned correctly in the
in the sensor’s corresponding groove. If the belt has only
grooves on one side, the flat side should be facing towards the sensor body.
After installation, the correct sensor adjustment should be verified, to ensure that the sen-
sor has been fitted with the right force. The clamping force is correct, if the edge of the
adjustment screw’s silver cylinder is positioned in the center of the green o-ring. If the edge
of the silver cylinder is not positioned inside the O-ring the sensor is incorrectly mounted.
Incorrectly adjusted: Correctly adjusted:
IMPORTANT:
DO NOT ADJUST SCREWS AS IT WILL VOID CALIBRATION OF SENSOR!
Belt versions:
OTIS
SCHINDLER
CONTITECH