7.C Installation of Sensors LSM-XL
Open both levers 1 as well as lever 2, open strap 3. Adjust the sensor by means of the ad-
justment screw 4 roughly to the rope diameter and mount the sensor onto the rope. Close
strap 3 and after lever 2.
Check the clamping force on indicator 5. If the clamping force is correct, half of the green
O-ring will be visible. If this is not the case, open lever 2 again and adjust the clamping
force by means of the adjustment screw 4. Close lever 2 again and close both levers 1.