Henning GmbH & Co. KG
page 36
19/02/2019
7.B Installation of Sensors LSM1 und LSM2
1.
Bring the clamp lever into
the “open” position. Place the sensor onto the
rope. If this is not possible, open the adjustment-screw several turns. When
the sensor is placed on the rope, turn the adjustment-screw in such a way,
that the marker matches the apropriate rope diameter on the label. This is
only a rough adjustment, the fine tuning will be done by the green o-ring on
the adjustment-screw.
2. Now close the clamp lever and taking care that the cable still runs correctly in the
sensor groove.
3. Connect the sensor LSM to the evaluation unit MSM12 via the USB cable.
Step 1
Step 2
Step 3