Henning GmbH & Co. KG
page 11
19/02/2019
If a connected sensor is defective,
ERR
will be displayed. The yellow warning-
triangle will show up, as soon as the calibration of the corresponding sensor has
expired.
A touch on one of the sensor-keys in the status bar will open a separate window showing
the data of the corresponding sensor (see also 6.C.1
“sensor-information”).
The suspension ratio of the elevator can be selected manualy by the user. The displayed
total weight is calculated by this factor. The individual weight displayed per sensor remains
unaf
fected (see also 6.D “Choosing Suspension Type”).
The total weight is the sum of all individual rope loads measured, converted according to
the suspension ratio (if applicable). The output can be selected in different weight units
such as kilogram, tons, Newton, English pounds, short tons or long tons.
The maximum individual rope load shows the actual load and the measuring channel num-
ber of the sensor which is loaded with the highest weight in the rope set. The minimum
individual rope load display shows the corresponding information for the rope with the lowest
load.
The maximum deviation shows the deviation (absolute as well as percentage) of the rope
with the greatest deviation from the average calculated from all ropes. The example in figure
shows a total weight of 1,529 kg distributed among nine ropes. This means that under ideal
conditions each rope should carry 177 kg. However, the rope at measuring channel 3 carries
245 kg, i. e. 68 kg (absolute) or 39 % more load(rounding errors possible).
The
calibration warning
will be displayed, if the last calibration of the evaluation unit
has been one year ago (or longer).
Save
Tensoning
Configuration