Henning GmbH & Co. KG
page 10
19/02/2019
6.C Main Display
Below, the main display of the mobile rope load evaluation unit MSM12 is shown. The upper
two lines display the status bar indicating the individual weight of each rope under the cor-
responding measuring chanel number.
Below, in the centre, the total weight resulting from the individual weights as well as the
maximum individual load, minimum individual load and the maximum deviation and the cor-
responding measuring channel numbers are indicated. At the right side four menu keys are
to be found which will be described in detail later. In the lower left-hand corner the charge
status of the batteries is displayed. On the upper left below the status bar the selected sus-
pension ratio is shown.
The individual sensor display shows the measured load of each connected rope load sensor.
Please note: The load in the status bar on top will not be calculated on the basis of
the selected suspension ratio.
Selected Suspention ratio
Sensor value 1 to 12 / Status Bar
Total weight
Max. single load
Min. single load
Max. deviation
Current state of
battery charge
Date / Time
Menu keys
!