33
6.3
Measuring the Calibration Values
When the print job has finished, the build platform is removed and the distance between the
printed columns is measured.
For how to remove the build platform see section 7.3 Removing the Build
Ensure the build platform is free of resin and the operator is wearing the correct PPE.
1.
Record the 4 measurements between the blocks.
2.
Enter these measurements in the software.
3.
Select ‘back’ to regenerate the calibration print using the new values
. Repeat the previous
steps.
Carry out this procedure 3 times to fully calibrate the printer. Or once the measured values are
160±0.2mm and 80±0.2mm
Ensure the previous build is removed from the build platform before creating another print.
For information how to do this see
section 7.3 Removing the Build