Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
37
Mounting base
Installation on concrete ceiling face, heavy-duty bracket
Installation of the anchor rod as per
approval ETA-12/0258:
- Drilled hole preparation
- Observe the anchoring depth and
the minimum edge distance!
- Drilled hole cleaning
- Fill drilled hole with mortar
- Slide the anchoring element into
the drilled hole
- Wait for the curing time
- The anchor rod must protrude 22-
26 mm from the concrete surface.
This has to be taken into account
when glueing. The anchor rod
cannot be shortened afterwards.
Legend
Anchor rod FIS A
Anchorage depth
Inserting the heavy-duty bracket:
First adjust the heavy-duty bracket
itself to the correct dimension of the
non-load-bearing layer and then
tighten the bracket with a suitable
socket wrench extension.
Legend
Anchor rod FIS A
Heavy-duty bracket
Self-locking nut M12
≥
55
≥
55
1
2
1
3
2
Installation Instructions and Instructions for Use
38
Subject to technical modifications
–
Date of Issue March/2021
Mounting base
Installation on concrete ceiling face, heavy-duty bracket
Inserting the intermediate plate:
Fasten with countersunk screws to the
heavy-duty bracket.
Legend
Intermediate plate
Countersunk screw M10x25
End plate and spacer plates:
The heavy-duty bracket can still be
finely adjusted with the aid of two
spacer plates of 5 mm each. A spacer
plate must always be used. Fasten the
end plate with four countersunk
screws.
Legend
Countersunk screw M10x30
End plate
Spacer plate 5 mm
1
2
3
2
1
Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
39
Mounting base
Installation on concrete ceiling face, heavy-duty bracket
Affixing the wall bracket type I:
Fasten the end plate and wall bracket
type I with hexagon head screws. The
end plate must be sealed all around
(Fischer Multi adhesive and sealant).
Legend
Wall bracket type I
End plate
Sealing joint all around
The sealing joints are maintenance joints that must be checked and
maintained at regular intervals in order to prevent consequential damage.
3
2
1
Installation Instructions and Instructions for Use
40
Subject to technical modifications
–
Date of Issue March/2021
Preparing the columns
Fix the corner joints for the rain gutters to the columns using two filister head screws
M8x20 per corner joint.
Legend
Corner column
Linking column
Central column
Corner column Wall
Linking column Wall
One oval head screw per corner connector must be mounted bare/electrically
conductive. This applies to all corner connectors on all column variants.
1
2
3
4
5