Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
33
Marking and fixing the wall brackets
Type self-supporting to wall
Hold the wall brackets to
the mounting base. Adjust
the brackets. Mark the
fixing points and screw the
brackets with the
appropriate mounting
material to the mounting
base. If you are unclear
about the mounting base
and material, consult a
specialist (e.g. a structural
engineer).
The wall brackets self-
supporting to wall ensure a
defined connection of a
self-supporting VENTUR
towards the wall. In this
way, a professional sealing
towards the wall with the
help of a wall connection
cover sheet can be
provided. In addition, the
bracket is used as
stabilization of the unit, but
does not have a load-
bearing function for the unit!
Legend
Corner column
Wall bracket Type self-supporting to wall
Horizontally adjusted with the help of a spirit level
Upper edge is horizontally projected to the wall
Guide line on the wall
Batten
Column flush with the wall
=
1
2
7
Installation Instructions and Instructions for Use
34
Subject to technical modifications
–
Date of Issue March/2021
Marking and fixing the wall brackets
Type self-supporting to wall
Attention should be paid
to the following:
The columns of the
VENTUR must be put to a
vertical position using a
spirit level; all sides must be
at a right angle with respect
to each other and the
complete upper
construction must be
horizontally aligned (see
Fig.).
Attention with vertical
shading elements:
If the
elements are not at a right
angle, the vertical shading
element get jammed when
it is raised or lowered.
Legend
FB
Complete width
FH
Complete height
SV+ Column lengthening
Complete width/ sloping
projection
Batten
270
SV+
30
90°
90°
90°
90°
90°
90°
FB
1
/AL
30
FB
1
/AL
FH
2
FB
1
/AL
Installation Instructions and Instructions for Use
Subject to technical modifications
–
Date of Issue March/2021
35
Mounting base
Installation on concrete
Installation of the anchor bolts as per
approval ETA-05/0069:
- Drilled hole preparation ø12 mm
Installation of the attachment:
- Tightening torque as per ETA-
05/0069
Legend
Concrete
Installation set 1; anchor bolt FAZ II M12
Bracket
Minimum anchoring depth - 70 mm
1
2
3
4
Installation Instructions and Instructions for Use
36
Subject to technical modifications
–
Date of Issue March/2021
Mounting base
Installation on concrete ceiling face, heavy-duty bracket
Register constructional situation:
- Thickness of the concrete ceiling
- Determination of the theoretical
position of the concrete ceiling
(consider differences is in the
ground)
- Determination of the non-bearing
layer ETICS (adhesive, insulation,
plaster)
Legend
Brickwork
Concrete ceiling
ETICS
Ceiling position
Thickness of the non-bearing layer
Exclude the shape of the heavy-
duty bracket under consideration of
the edge distances
Using a "multi-cutter" tool is
recommended for cutting out the
insulation.
The two upper and lower drilled holes of the bracket should be preferred
for installation. For ceiling thicknesses of <200mm, the middle hole must
be used in order to maintain the edge distances. Otherwise the third drilled
hole serves for refitting potential errors (e.g. wrong assessment of the
constructional situation or position of the concrete ceiling).
180
≥
1
3
2
5
4
4