OPERATION
7-2
MSHF • 7295-026A
- ground supports and the quality of
the ground
- electrical connections
- protective covers (presence and
securing)
- securing of the platform extension
- operation of the limit switches
- no obstacles in the path of the
platform
- oil leaking from the drive units and
chassis motor
- functioning of the motor brakes
(section 7.4).
2.
Connect the electrical power supply.
3.
Close the gates.
4.
Remove the padlock from the main
switch.
5.
Place the main switch in position I or
II (the position depends on the
direction of phase rotation of the
power supply).
6.
Check that the EMERGENCY push-
button on the control box is switched
off (the push-button must be pulled
out). On a twin mast unit release both
emergency push buttons.
7.
If the display shows code 02 and the
phasegaurd light does not burn, the
main switch must be set in the other
position. The display will show code
00. If the electric safety circuit (gates,
etc.) is closed the blue light on the
control box will burn.
Only single-mast. Eccentric overload
check:
During a few seconds there will be
sounding a buzzer and a light will
flash on the control box.
Fig.7-1
Main switch
Fig.7-2
Emergency push-button
Summary of Contents for MSHF
Page 4: ...IV MSHF 7295 026A...
Page 10: ...X MSHF 7295 026A Fig 1 Dimensions...
Page 14: ...TECHNICAL DETAILS 1 4 MSHF 7295 026A Fig 1 6 Drive unit...
Page 16: ...TECHNICAL DETAILS 1 6 MSHF 7295 026A Fig 1 7 Chassis Fig 1 8 Ground frame...
Page 30: ...SAFETY 3 4 MSHF 7295 026A...
Page 70: ...DISASSEMBLY AND TRANSPORT 8 4 MSHF 7295 026A...
Page 80: ...MACHINE DISPOSAL 11 2 MSHF 7295 026A...
Page 83: ...APPENDICES 1 MSHF 7295 026A...
Page 84: ...APPENDICES 2 MSHF 7295 026A...