ASSEMBLY AND ANCHORING
6-24
MSHF • 7295-026A
Fig.6-47 Lightning protection
6.10 Adjusting the EMOS system
1.
The switch can only been turned with
the correct key. Set the EMOS switch
(1,2,3) in position 2. The config panel
starts to flash.
2.
The program can be changed with
the UP or DOWN button on the
control box.
3.
Set the desired program
(See table chapter 1.7).
4.
Set the EMOS switch on position 1.
5.
The config panel shows the adjusted
value.
6.
Remove the key.
6.11 Lightning protection
1.
Fasten the connecting cable between
the chassis/ground frame and the
mast.
Cable specifications:
- Insulated copper, 16 mm² cross
section.
2.
Mount the connection between the
chassis/ground frame and the earth.
This connection must satisfy the
following specification:
DIN VDE 0185, part II, §5.2
The cable supplied (25 mm² / 0.0039
in² cross section, 25 m / 82 ft long)
must be connected to the terminal
box on the building site.
Fig.6-46 Adjusting EMOS