ERS COMPACT

From the main function generator screen, you can go back to the first screen of FC table configuration and use a 

formerly locked 

Import/Export 

-> 

Save

 

action button, to save the calculated table to USB stick. In order to do so, 

follow the on-screen instructions. The table can be used to analyze the values or to visualize it in Excel or similar 
tools.

 

How to work with the FC table function

1. 

With  an  appropriate  load  connected,  for  example  a 

DC-DC  converter,  start  the  function  by  switching  the 

DC output on.

2. 

The output voltage will be set depending on the load 

current, which is defined by the connected load, and will 

decrease with increasing current. Without any load, the 

voltage will rise to the adjusted Uoc value.

3. 

Stop the function run anytime by the stop button or by 

switching off the DC output.

3.11.15 

Extended PV function according to EN 50530

3.11.15.1 

Introduction

This extended PV table function according to norm EN 50530 is used to simulate solar panels in order to test 

and rate solar inverters. It’s also based on the XY generator, same as the simple PV table function from 

3.11.13

but enables more specific tests and evaluations due to adjustable parameters. Which parameters are available 

is explained below. The device can, however, only calculate and run the PV curve. Evaluation of a solar inverter, 

as described in the norm paper, is only possible with our software 

EA Power Control

. It will, amongst other result 

data, determine the inverter’s efficiency.
The impact of the parameters on the PV curve and the simulation is described in the norm paper of EN 50530, 

which users can refer to in case more detailed description is required. This section only deals about configuration 

and control of the PV simulation.

3.11.15.2 

Differences to the basic PV function

The extended PV function has five additional or different characteristics compared to the simple PV function:

• 

The simulation distinguishes between a single test run and an automatic test run, called day trend, which is based 

upon a user-defined curve built from up to 100,000 points

• 

There are two invariable and one variable panel technology available to choose from

• 

There are more parameters available to adjust during runtime

• 

It allows for data recording during runtime and to save the data either to USB stick or read via digital interface

• 

It allows to select between two different parameter sets to adjust during runtime

3.11.15.3 

Technologies and technology parameters

When configuring the PV simulation it’s required to select the solar panel technology to simulate. The technologies 

cSI

 and 

Thin film

 

are invariable in their parameters, while technology 

Manual

 

is variable in all parameters, but 

within specific limits. This allows for the variation of the simulation and when copying the fixed parameter values 

from 

cSi

 

or 

Thin film

 

to 

Manual

, it even enables their variation as well.

One advantage of the invariable technologies is that their technology parameters are automatically set to their 

defined defaults in the configuration procedure.

Overview of the technology parameters used in the PV curve calculation and their defaults:

Abbr.

Name

Manual

cSI

Thin film

Unit

FFu

Fill factor for voltage

>0...1 (0.8)

0.8

0.72

-

FFi

Fill factor for current

>0...1 (0.9)

0.9

0.8

-

Cu

Scaling factor for U

OC

 

(1

>0...1 (0.08593)

0.08593

0.08419

-

Cr

Scaling factor for U

OC

 

(1

>0...1 (0.000109)

0.000109

0.0001476

m²/W

Cg

Scaling factor for U

OC

 

(1

>0...1 (0.002514)

0.002514

0.001252

W/m²

alpha

Temperature coefficient for I

SC

 

(2

>0...1 (0.0004)

0.0004

0.0002

1/°C

beta

Temperature coefficient for U

OC

 

(1

-1...<0 (-0.004)

-0.004

-0.002

1/°C

(1 Uoc = Open circuit voltage of a solar panel

(2 Isc = Short-circuit current (=max. current) of a solar panel

Summary of Contents for ERS Compact Series

Page 1: ...www heinzinger com Betriebsanleitung User Manual Bidirectional Power Supply System Heinzinger ERS Compact Series...

Page 2: ...ore installation and use 36 2 3 2 Preparation 36 2 3 3 Installing the device 39 2 3 4 Connection to water supply WC models 40 2 3 5 Connection to AC supply 42 2 3 6 Connection to DC loads or DC source...

Page 3: ...nction 85 3 11 8 Trapezoidal function 86 3 11 9 DIN 40839 function 86 3 11 10 Arbitrary function 87 3 11 11 Ramp function 91 3 11 12 IU table function XY table 92 3 11 13 Simple PV photovoltaics funct...

Page 4: ...Heinzinger electronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 4 ERS COMPACT...

Page 5: ...eneral notices in this document are shown in a box with a symbol as follows Symbol for a life threatening danger Symbol for general safety notices instructions and damage protection bans or important...

Page 6: ...able voltage and current source or only as a variable current sink Typical application for a voltage source is DC power supply to any relevant user including when used as battery charger to test charg...

Page 7: ...ntended The equipment is only approved for use within the connection limits stated on the product label Do not insert any object particularly metallic through the ventilator slots Avoid any use of liq...

Page 8: ...rk station via a risk assessment introduce the necessary steps in the operating procedures for the local conditions regularly control that the operating procedures are current update the operating pro...

Page 9: ...s of the preset limit Non critical protects the load or source from excessive power consumption Signal PF Power Fail DC terminal shutdown due to AC undervoltage or defect in the AC section Critical on...

Page 10: ...2 A Overpower protection range 0 33000 W 0 33000 W 0 33000 W Temperature coefficient K Voltage set values current set values 100 ppm Capacitance approx 25380 F 25380 F 5400 F Voltage regulation genera...

Page 11: ...ing WC Water IP20 Ambient temperature 0 50 C 32 133 F Storage temperature 20 70 C 4 158 F Humidity 80 not condensing Standards EN 61010 1 2007 11 EN 50160 2011 02 EN 61000 6 2 2016 05 EN 61000 6 3 201...

Page 12: ...Max 5 UNom Max 5 UNom Voltage regulation power supply Load regulation at 0 100 IOUT 0 05 UNom 0 05 UNom 0 05 UNom Rise time 10 90 UOUT Max 30 ms Max 30 ms Max 30 ms Transient time after IOUT 1 5 ms 1...

Page 13: ...Cooling WC Water IP20 Ambient temperature 0 50 C 32 133 F Storage temperature 20 70 C 4 158 F Humidity 80 not condensing Standards EN 61010 1 2007 11 EN 50160 2011 02 EN 61000 6 2 2016 05 EN 61000 6 3...

Page 14: ...x 5 UNom Max 5 UNom Voltage regulation power supply Load regulation at 0 100 IOUT 0 05 UNom 0 05 UNom 0 05 UNom Rise time 10 90 UOUT Max 30 ms Max 30 ms Max 30 ms Transient time after IOUT 1 5 ms 1 5...

Page 15: ...Cooling WC Water IP20 Ambient temperature 0 50 C 32 133 F Storage temperature 20 70 C 4 158 F Humidity 80 not condensing Standards EN 61010 1 2007 11 EN 50160 2011 02 EN 61000 6 2 2016 05 EN 61000 6 3...

Page 16: ...V ERSC 200 420 US208V AC supply Voltage range L L 187 228 V AC Connection 3ph PE DC terminal Max power PMax 15000 W 15000 W 15000 W Overpower protection 0 16500 W 0 16500 W 0 16500 W Power regulation...

Page 17: ...Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 17 ERS COMPACT A Power switch B Control panel Figure 1 Front view sta...

Page 18: ...nger electronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 18 ERS COMPACT Figure 2 Front view water cooled v...

Page 19: ...nzinger electronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 19 ERS COMPACT Figure 3 Front view Slave versi...

Page 20: ...83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 20 ERS COMPACT C Control interfaces digital analog F Share Bus connectors J AC plug D Master slave bus ports G DC terminal type 1...

Page 21: ...tronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 21 ERS COMPACT Figure 5 Rear view water cooled version K W...

Page 22: ...inzinger electronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 22 ERS COMPACT Figure 6 Rear view Slave versi...

Page 23: ...Heinzinger electronic GmbH Phone 49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 23 ERS COMPACT Figure 7 Side view...

Page 24: ...49 0 8031 2458 0 www heinzinger com Anton Jakob Str 4 83026 Rosenheim Fax 49 0 8031 2458 58 info heinzinger de Germany Page 24 ERS COMPACT Figure 8 Top view example of a standard model with DC termina...

Page 25: ...can be operated with the fingers or with a stylus 2 Rotary knob with push button function Left knob turn voltage set value adjustment Left knob push shift the decimal position cursor of the voltage s...

Page 26: ...e module For a detailed description see section 1 9 7 The control panel Slave models 1 On Off button Can be used to switch the DC terminal on or off during manual operation while LED Remote is off 2 U...

Page 27: ...on the rear side as well as a galvanically isolated analog interface Via optional plug in interface modules other digital interfaces such as for RS232 Profibus ProfiNet ModBus TCP CAN CANopen or Ether...

Page 28: ...nd the programming of the device using those interfaces can be found in separate documentation It s usually available on the USB stick which is included with the device or as PDF download on the manuf...

Page 29: ...t Additional status Status area Actual current display Current set value input Touch area for rotary knob assignment DC terminal status Actual power display Power set value input Indicator source sink...

Page 30: ...he device has been locked by the user explicitly against remote control Alarm Alarm condition which has not been acknowledged or still exists Event A user defined event has occurred which is not yet a...

Page 31: ...1 A MS 1000 kW 5 0 1 kW 1000 5 0 1 750 V 4 0 1 V MS 10000 A 5 1 A 1000 V 5 0 1 V MS Master slave 1 9 6 5 USB port front side The frontal USB port located to the right of the rotary knobs is intended f...

Page 32: ...erent and or additional to log data of normal USB logging is recorded 3 11 16 7 mpp_result_ nr csv Result data from MPP tracking mode 4 in form of a table with 100 data groups Umpp Impp Pmpp 3 11 17 6...

Page 33: ...ice would regulate it to the last values it has stored Since all the DC terminal related values aren t displayed operating that button has to be done with caution 1 9 8 USB port rear side The USB port...

Page 34: ...obtained from us or electronics stores Share bus operation requires to connect only identical device models Follow ing power supply and electronic load series are compatible on this Share bus ERSC 100...

Page 35: ...e automatically detecting the type of message The network setup can be done manually or by DHCP Transmission speed and duplex mode are on automatic mode If remote control is in operation the Ethernet...

Page 36: ...mpleteness using the delivery note and or parts list see section 1 9 3 Scope of delivery An obviously damaged device e g loose parts inside damage outside must under no circumstances be put in operati...

Page 37: ...ination 2 One ERSC 10000 with one or multiple ERSC 10000 Slave This is the intended combination for models of ERSC 10000 Slave series Advantage of this combination lower costs Disadvantage of this com...

Page 38: ...ic grid The devices can t work without this functionality The goal is to consume the recovered energy completely in the local power grid of a company or plant In case it can occur that more energy is...

Page 39: ...with lockable doors or by applying further measures additional cover etc A device in a 19 chassis will usually be mounted on suitable rails and installed in 19 racks or cabinets The depth of the devic...

Page 40: ...talled and running there is one primary value left to supervise permanently the so called dew point Depending on the temperature of water on the intake in combination with the humidity of ambient air...

Page 41: ...54 4 56 3 58 3 59 8 61 4 63 1 67 F 44 3 47 49 6 52 54 1 56 1 58 1 59 9 61 6 63 3 64 8 68 F 46 48 8 51 3 53 6 55 8 58 59 9 61 7 63 4 65 1 66 6 70 F 47 5 50 4 52 9 55 3 57 6 59 7 61 6 63 4 65 2 66 7 68...

Page 42: ...0 480 V No matter what particular version the device is standard WC or Slave the ratedAC supply voltage on the type label is important The models for 380 400 480 V use a regular three phase supply wit...

Page 43: ...PE conductor is imperative and must always be wired The N conductor if present in the cable can be wired to the free slot on the AC plug For the wiring cross section the power of the device and the ca...

Page 44: ...e grid current see schematic below and this can lead to an overload of the existing electric installation Considering any two outlets no matter of what kind they are there is usually no extra fusing i...

Page 45: ...and average ambient temperature up to 30 C 86 F we recommend up to 40 A 6 mm up to 60 A 16 mm up to 80 A 25 mm up to 120 A 35 mm up to 180 A 70 mm up to 240 A 2x 35 mm up to 420 A 2x 95 mm up to 1000...

Page 46: ...dation for cables up to 5 m 16 4 ft use at least 0 5 mm Sense cables shouldn t be twisted but laid close to the DC cables i e Sense cable close to DC cable to the load etc to damp or avoid possible os...

Page 47: ...lot cover is mounted in order to avoid internal dirtying of the device and changes in the air flow standard models with air cooling Installation steps 1 2 3 Remove the slot cover If need ed use a scre...

Page 48: ...Class CDC device and is usually integrated in current operating systems such as Windows 7 or 10 But it s strongly recommended to use and install the included driver installer on USB stick to gain max...

Page 49: ...ng voltage current and power to the adjusted values and hold them constant if possible These circuits follow typical laws of control systems engineering resulting in different operating modes Every op...

Page 50: ...active the condition CC mode active will be indicated on the graphics display by the abbreviation CC and this message will be passed as a signal to the analog interface as well stored as status which...

Page 51: ...a natural characteristic The load attempts to set the internal resistance to the user defined value by determining the input current depending on the input voltage according to formula IIN UIN RSET wh...

Page 52: ...cs and stability criteria When working in sink mode the device becomes an electronic load which is characterized by short rise and fall times of the current which are achieved by a high bandwidth of t...

Page 53: ...ce can automatically switch the DC terminal back on depending on the setting of parameter DC Terminal State after OT alarm Also see section 3 5 3 1 for more information The alarm will remain in the di...

Page 54: ...alarm can t be acknowledged the usual way It requires to pow er cycle the unit During normal operation of the power supply this alarm should not trigger There are however situations which can trigger...

Page 55: ...either on or off All set values are always saved and restored For the time of the start phase the analog interface can signal undefined statuses on its digital outputs This must be ignored until the d...

Page 56: ...ource mode and 3 5 6 Manual adjustment of set values standard models Analog interface Range Selects the voltage range for the analog set values actual values and reference voltage output 0 5 V Range i...

Page 57: ...pin 10 CMON voltage on pin 9 VMON Actual current EL Pin 10 only signals the actual current in sink mode EL Actual current PS Pin 10 only signals the actual current in source mode PS Mode A Current of...

Page 58: ...where the display isn t supposed to be permanently on It s identical to the setting in menu HMI setup Initialize system Tapping this touch area will repeat the initialization of the master slave syst...

Page 59: ...ta packets using higher values In group Protocols you can disable one of the two supported communication protocols ModBus and SCPI This can help to avoid mixing both protocols and to receive unreadabl...

Page 60: ...re a subnet mask can be defined if the default subnet mask is not suitable Gateway Here a gateway address can be allocated if required DNS address Here the addresses of the first and second Domain Nam...

Page 61: ...of status from the adjusted Base ID Cyclic Read Range 20 5000 ms Default 0 ms deactivated Cyclic Read Time Set PS Activation deactivation and time setting for the cyclic read of set values of U I sour...

Page 62: ...Interface monitoring Default values off 5 s Range 5 65535 Protocols Communication protocols Enables or disables SCPI or ModBus communication protocols for the device The change is immediately effectiv...

Page 63: ...s 8000 W then the set value first would have to be reduced to 6000 W or less in order to set P max down to 6000 W 3 5 5 Changing the operating mode In general the manual operation of the device distin...

Page 64: ...mity to the adjusted value How to adjust set values U I P or R with the rotary knobs 1 First check if the value you want to change is already assigned to one of the rotary knobs The main screen displa...

Page 65: ...he USB stick and the generated log files refer to section 1 9 6 5 USB port front side The logging stores files of CSV format on the stick where the layout of the log data is the same as when logging v...

Page 66: ...R set and R actual are only recorded if R mode is active refer to section 3 5 5 Unlike the logging on PC every log start here creates a new log file with a counter in the file name starting generally...

Page 67: ...iction of the temporal run of the actual values of voltage current and power called the graph It isn t a recording feature whatsoever For data recording in the background there is still the USB loggin...

Page 68: ...the status Local will be displayed top right Activating the inhibit can be useful if the device is remotely controlled by software or some electronic device but it s required to make adjustments at th...

Page 69: ...ands can be found in the document Programming guide ModBus SCPI CLS SOURce POWer PROTection LEVel ESE SOURce POWer PROTection LEVel ESE SOURce RESistance ESR SOURce RESistance IDN SOURce RESistance LI...

Page 70: ...ng Interface monitoring is a configurable functionality introduced in firmwares KE 2 06 and HMI 2 08 Its goal is to monitor or supervise the communication line between the device and a superior contro...

Page 71: ...l configured for the default see section 3 5 3 Configuration via the menu All set values are always additionally limited to the corresponding adjustment limits U max I max etc which would clip setting...

Page 72: ...between manual and remote control Remote LOW ULow 1 V Manual HIGH UHigh 4 V Manual if pin not wired Voltage range 0 30 V IMax 1 mA at 5 V ULOW to HIGH typ 3 V Rec d sender Open collector against DGND...

Page 73: ...an t drive any load only sink small current as shown in the diagram with a relay as example V 2 AGND Analog Output AO Output from an operation amplifier circuit low impedance See specifi cations table...

Page 74: ...can be switched on or off by pushbutton or digital command LOW Inverted HIGH Inverted The DC terminal will be switched off and locked Later it can be switched on again by toggling the pin During lock...

Page 75: ...r from external If the voltage set value becomes lower than the actual voltage the device will switch to source mode e Determining the actual operation mode between source and sink The limited number...

Page 76: ...Device alarm and event handling Important to know When switching the DC input sink mode of the device off while a current limited source still supplies energy the output voltage of the source can ris...

Page 77: ...aces Safety OVP Safety OverVoltage Protection Only featured with the 60 V models Triggers a special OVP alarm in case the voltage on the DC terminal exceeds the rigid threshold of 101 rated voltage Th...

Page 78: ...ds the defined threshold 0 A INom OPD OverPower Detection Triggers an event if the DC power exceeds the defined threshold 0 W PNom These events shall not be confused with alarms such as OT and OVP whi...

Page 79: ...p up will disappear and the HMI remains locked In case the additional PIN code lock has been activated in the Lock screen another re quester will pop up asking you to enter the PIN before it finally u...

Page 80: ...including language a profile change can also be accompanied by a change in HMI language On calling up the menu page and selecting a profile the most important settings can be seen but not changed How...

Page 81: ...stick loadable current curve table CSV PV FC Functions to simulate a solar panel PV function or fuel cells FC function both with table calculation based upon adjustable parameters also for EN 50530 B...

Page 82: ...re then constants and have a limiting effect That means if for example a voltage of 100 V is set in source mode for the DC output a load is connected and a sine wave function should operate on the cur...

Page 83: ...nction exclusively in sink or in source mode it s recommended to set the set values I P of the opposite mode to 0 The global limits of U I and P become instantly active when coming to the main screen...

Page 84: ...t The scheme on the left depicts the mixed mode run yellow source mode active green sink mode active While the amplitude is always an absolute value the offset can be positive or negative I mode only...

Page 85: ...d work in sink mode if the external voltage on the DC terminal is higher than the highest point offset amplitude of the wave and the current setting I Sink is not 0 The following parameters can be con...

Page 86: ...ble time values With suitable settings the trapezium can be deformed to two triangular or two rectangular pulses It has therefore universal use 3 11 9 DIN 40839 function This function is based on the...

Page 87: ...equency is shaped between start and end When both start frequency and end frequency are 0 Hz the AC overlay has no impact and only the DC part is effective Each sequence point is allocated a sequence...

Page 88: ...ves to be created For instance with f 1 Hz and time 3 s three full waves would be generated if the angle is 0 and reciprocally the same for f 3 s and time 1 s Start DC t U I Start AC End AC Seq time E...

Page 89: ...I Example 7 Focusing 2 cycles of 1 sequence point One sequence point configured as in example 3 is run Since the settings define that the end offset DC is higher than the start the second run will re...

Page 90: ...Column Connected to HMI parameter Range A AC start See table in 3 11 10 Arbitrary function B AC end See table in 3 11 10 Arbitrary function C Start frequency 0 10000 Hz D End frequency 0 10000 Hz E A...

Page 91: ...wave and the current setting I Sink is not 0 The following parameters can be configured for a ramp function Parameter Range Description Start End 0 UNom or INom INom Start end point of the ramp Both v...

Page 92: ...B stick that is formatted in FAT32 In order to load the file it has to meet following specifications The file name always begins with IU not case sensitive The file must be a text file of type Excel C...

Page 93: ...oblems Check the technical specifications of the solar inverter and probably contact the inverter s manufacturer for an evaluation 3 11 13 3 Usage In the PV function which is based upon the XY generat...

Page 94: ...started when the user switches the DC output on Irradiance 0 100 U I Uoc MPP From the main function generator screen you can go back to the first screen of PV table function and use a for merly locke...

Page 95: ...he curve to be calculated Points 2 3 I 0 A INom Point 4 Isc 0 A INom Maximum output current of the fuel cell short circuit situation U 0 V UNom Global voltage limit should be Uoc P 0 W PNom Global pow...

Page 96: ...ed This section only deals about configuration and control of the PV simulation 3 11 15 2 Differences to the basic PV function The extended PV function has five additional or different characteristics...

Page 97: ...between two succeeding curve points Hence it should be considered to run the day trend with or without interpolation The day curve points have to be loaded into the device either from a CSV file on US...

Page 98: ...n use such small steps in voltage or current may not be doable However the device would try to set the first intermediate step with 75 0138 V and 18 0027 A 3 11 15 7 Data recording There is the option...

Page 99: ...an result in a PV curve which doesn t work as expected When resetting the device these values are reset to defaults which are the same as with technology cSI Also see the overview in 3 11 15 3 It mean...

Page 100: ...t by the rotary knobs because with every step of the knob the curve would be re calculated The screen example on the right shows simulation mode E T In case any of the day trend modes would have been...

Page 101: ...read from the device via digital interface partly or completely or stored to USB stick This can serve to verify the adjusted parameters When running mode DAY E T or DAY U I this makes less sense beca...

Page 102: ...For a projected CR operation it s similar Current and power should then be set to maximum For Dynamic discharge mode there is also a power setting but it can t be used to run the dynamic battery test...

Page 103: ...Charge end current 0 INom Current threshold in Ampere upon which the charging would stop 3 11 16 4 Settings for the dynamic test mode The following parameters can be configured for the dynamic test ba...

Page 104: ...onfiguration of all test modes there is the option to enable the USB logging feature With a USB stick plugged and formatted as required see 1 9 6 5 the device can record data during the test run direc...

Page 105: ...lightly above UOC ISC is used as a upper limit for the current so the device would not try to draw more current than the panel is spec ified for Following parameters can be configured for tracking mod...

Page 106: ...tage values then track this curve measure current and power and return the results in up to 100 sets of acquired data The curve points can only be loaded from a USB stick Start and end point can be ad...

Page 107: ...are always set to max Format of the result data file for naming convention see section 1 9 6 5 Legend Column A actual voltage of points 1 100 UMPP Column B actual current of points 1 100 IMPP Column...

Page 108: ...ause DC minus is the reference for the Share bus Principle view without load or source Share bus connection Master slave bus 3 12 1 1 Restrictions Compared to normal operation of a single device maste...

Page 109: ...t is going to be used the Share bus must be connected as well How to connect the digital master slave bus 1 Switch off all units and connect the master slave bus with network cables CAT3 or better cab...

Page 110: ...unit will reconfigure after initialization and all set values are reset The master now dis plays the set and actual values of the total system Depending on the number of units the adjustable current a...

Page 111: ...master unit is cut from AC supply power switch blackout and comes back later the unit will automati cally initialize the MS system again finding and integrating all active slaves In this case MS can...

Page 112: ...supplier with or without guarantee If a return for checking or repair is to be carried out ensure that the supplier has been contacted and it s clarified how and where the equipment should be sent the...

Page 113: ...th must not exceed the max error of the device under calibration 4 3 2 Preparation For a successful calibration and readjustment a few tools and certain ambient conditions are required A measurement d...

Page 114: ...he manufacturer No RMA number is needed It s sufficient to package the equipment adequately and send it together with a detailed description of the fault and if still under guarantee a copy of the inv...

Reviews: