ERS COMPACT
Group
Parameters & description
Analog interface Pin 14
Pin 14 of the analog interface (see section
3.6.4.5
) is by default assigned to only signal the
device alarm OVP. This parameter allows to also enable signaling the device alarms OCP
and OPP in 7 possible combinations:
•
Alarm OVP
= Signals only OVP
•
Alarm OCP
= Signals only OCP
•
Alarm OPP
= Signals only OPP
•
Alarm OVP+OCP
= Signals OVP or OCP
•
Alarm OVP+OPP
= Signals OVP or OPP
•
Alarm OCP+OPP
= Signals OCP or OPP
•
Alarm OVP+OCP+OPP
= Signals any of all three
Pin 15
Pin 15 of the analog interface (see section
3.6.4.5
) is by default assigned to only signal the reg-
ulation mode CV. This parameter allows to enable signaling the DC terminal status (2 options):
•
Regulation mode
= Signals only CV reg mode on pin 15
•
DC status
= Signals the DC terminal status on pin 15
VMON/CMON
Configures how the actual values of voltage and current are represented. If not listed otherwise,
the setting doesn’t affect the selected signal range (0-5 V or 0-10 V).
•
Default
= Current (sink or source mode) on pin 10 (CMON), voltage on pin 9 (VMON)
•
Actual current (EL)
= Pin 10 only signals the actual current in sink mode (EL)
•
Actual current (PS)
= Pin 10 only signals the actual current in source mode (PS)
•
Mode A
= Current of source mode (PS) on pin 9, current of sink mode (EL) on pin 10, the
voltage is not signaled in this mode
•
Mode B
= Current of sink mode (EL) on pin 9, current of source mode (PS) on pin 10, the
voltage is not signaled in this mode
•
Actual current (EL) + (PS)
= Pin 10 signals a combination of the current in sink and source
mode as -100%...0...100% whereas 0% is put in the center of the analog signal range, it
means either at 5 V or 2.5 V. Each of both actual values only has half resolution.
DC terminal
State after power ON
Determines the condition of the DC terminal after power-up.
•
Off
= DC terminal is always off after switching on the device.
•
Restore
= Default, DC terminal state will be restored from last switch-off.
State after PF alarm
Determines the condition of the DC terminal after a power fail (PF) alarm:
•
Off
= Default, DC terminal remains off
•
Auto
= DC terminal will switch on again after the PF alarm cause is gone, if it has been
switched on before the alarm occurred
State after remote
Determines the condition of the DC terminal after leaving remote control either manually or
by command:
•
Off
= Default, DC terminal will always be off after leaving remote control
•
Auto
= DC terminal will keep the last state