ERS COMPACT
Controller
(DR)
Commu-
nication
(KE)
HMI
MS
USB
USB
Share &
Sense
Block diagram
=
≈
=
≈
AC
DC
Commu-
nication
(KE)
Power block
PSB 10000 Slave
1.9.3
Scope of delivery
1 x Bidirectional power supply device
2 x Remote sensing plugs
1 x 1.8 m (5.9 ft) USB cable
1 x Set of DC terminal covers (only with models from 360 V)
1 x Sense terminal cover
1 x USB stick with documentation and software
1 x AC connector plug (clamp type)
1.9.4
Accessories
For the standard version, with or without water cooling option installed, the following accessories are available:
IF-AB
Interface modules
Pluggable and retrofittable, digital interface modules for RS232, CANopen, Profibus,
ProfiNet, ModBus TCP, EtherCAT or CAN are available. Details about the interface mod
-
ules and the programming of the device using those interfaces can be found in separate
documentation. It’s usually available on the USB stick, which is included with the device,
or as PDF download on the manufacturers website.
EABS
Battery simulation
EABS is short for EA Battery Simulator and is an optionally available, USB dongle li
-
censed Windows software. In combination with the bidirectional power supplies of series
ERSC 9000, ERSCE 9000, ERSC 10000 and ERSCE 10000 it simulates either a single
lithium-ion cell or lead-acid battery or multiple in series and/or parallel connection. The
simulation works with battery typical values such as capacity, temperature, state of charge,
internal resistance and cell voltage, plus adjustable test conditions.
ENS2
NS protection
NS protection device in form of a 3U front plate with control panel for 19“ cabinets in
several variants with or without contactors:
Version
Contactors incl. /
max. power rating
Application
ENS2
none / -
Cabinet systems up to 240 kW
ENS2 10,5kW
yes, 2 / 10,5 kW
Single ELR/ERSC/ERSCE up to
10.5kW
ENS2 30kW
yes, 2 / 30 kW
Single ELR/ERSC/ERSCE up to
30kW