ERS COMPACT
General display and setting ranges:
Display
Unit
Range
Description
Actual voltage
V
0.2-125% U
Nom
Actual value of the voltage on the DC terminal
Set value of voltage
V
0-102% U
Nom
Set value for limiting the DC voltage
Actual current
A
0.2-125% I
Nom
Actual value of the current on the DC terminal
Set values of current
A
0-102% I
Nom
Set value for limiting the DC current
Actual power
W, kW 0.2-125% P
Nom
Actual value of power according to P = U * I
Set values of power
W, kW 0-102% P
Nom
Set value for limiting DC power
Set value of resistance
Ω
x
(1
-102% R
Max
Set value for the internal resistance
Adjustment limits
ditto
0-102% nom
U-max, I-min etc., related to the physical quantities
Protection settings
ditto
0-110% nom
OVP, OCP, OPP (related to U, I and P)
(1
Lower limit for resistance set value varies. See tables in section
1.8.3
•
Status display (upper right)
This area displays various status texts and symbols:
Display
Description
The HMI is locked
The HMI is unlocked
Remote:
The device is under remote control from....
Analog
...the built-in analog interface
ETH
...the built-in Ethernet interface
USB
& others
...the built-in USB port or a plug in interface module
Local
The device has been locked by the user explicitly against remote control
Alarm:
Alarm condition which has not been acknowledged or still exists.
Event:
A user defined event has occurred which is not yet acknowledged.
MS mode: Master (n Sl)
Master-slave mode activated, device is master of n slaves
MS mode: Slave
Master-slave mode activated, device is slave
FG:
Function generator activated, function loaded (only in remote control)
/
Data logging to USB stick active or failed
•
Area for assigning the rotary knobs and DC terminal status
The two rotary knobs next to the display screen can be assigned to various functions. This area shows the actual
assignments. These can be changed by tapping this area, as long as the panel is not locked.
The physical quantities on the depiction of the knob show the current as-
signment. The left knob is always assigned to the voltage (U), while the
right knob can be switched by tapping on the depiction. Furthermore, the
DC terminal status is indicated by two LEDs (green = on).
There are following possible rotary know assignments:
U I
U P
U R
Left rotary knob: voltage
Right rotary knob: current
Left rotary knob: voltage
Right rotary knob: power
Left rotary knob: voltage
Right rotary knob: resistance
(only with R mode active)
Due to the device having two set values each for current, power and resistance, tapping multiple times will cycle
through the 4 resp. 6 assignable set values for this knob. The currently not selected set values can’t be adjusted
via the rotary knob, unless the assignment is changed.