Heat & Glo • HE36CLX-S • 2183-900 Rev. H • 1/14
42
Figure 14.3 Exhaust Safety Switch
NOTICE:
DO NOT
wire 110-
120 VAC to
Equipment
Interface
Module.
F. Junction Box Installation
To wire the junction box from the
INSIDE
of the appliance:
• Disengage the latch and pull the
fi
rebox out. Refer to
Section 16 for instructions and see Figure 16.1.
• Remove the screw attaching the junction box/receptacle
to the outer shell, rotate the junction box inward to dis-
engage it from the outer shell.
• Pull the electrical wires from outside the appliance through
the opening into the valve compartment and secure wires
with a Romex connector.
• Make all necessary wire connections to the junction box/
receptacle and reattach the junction box/receptacle to
the outer shell.
NOTICE:
Hearth & Home Technologies recommends
that this appliance be wired on its own circuit with its own
circuit breaker.
CAPACITOR
SAFETY
SWITCH
WARNING! Risk of Shock!
Capacitor contains stored
voltage. Discharge capacitor before servicing.
G. Convection Blower Safety Switch
The convection blower is wired through a safety switch so
the convection blower will not operate when the
fi
rebox is
disengaged from the outer wrap and/or being serviced.
See Figure 14.6.
WARNING! Risk of Injury! DO NOT
bypass the safety
switch. Fan blades will cause injury.
Figure 14.6 Capacitor and Safety Switch
Figure 14.4 Junction Box Detail
Figure 14.5 Power Cord from Wire Harness Plugged into
Junction Box
This appliance is equipped with an exhaust safety switch
that will shut down the appliance in the event of an exhaust
hose disconnection. See Figure 14.3. The exhaust safety
switch is wired to the supplied junction box to the “FAN”
terminals. See Figure 14.4. The power cord from the wire
harness is then plugged into the “FAN” receptacle on the
supplied junction box. See Figure 14.5.
EXHAUST
SAFETY
SWITCH
JUNCTION
BOX
POWER CORD
FROM WIRE
HARNESS