35
Heat & Glo • HE36CLX-S • 2183-900 Rev. H • 1/14
APPLIANCE FRONT
Figure 11.3. Upper Inducer Housing Tube Connected to Field-
Supplied Funnel
5. Insert 3/8 inch (ID)
fi
eld-supplied funnel into tube. See
Figure 11.3.
6. Pour one quart propylene glycol (swimming pool/RV
antifreeze) into funnel.
NOTICE: DO NOT
use any antifreeze other than propylene
glycol. Damage to plastic components may occur.
Propylene glycol should run through inducer housing,
fi
ll condensate trap, and over
fl
ow into condensate drain.
Propylene glycol should remain in condensate system. It
does not need to be removed before appliance startup.
7. Remove funnel and reconnect upper inducer tube to
the housing.
8. Disengage support wheels, return
fi
rebox to closed
position and engage latch. See Section 16.D and
16.E.
9. Reconnect electrical supply.
10. Turn on gas supply at valve.