Access Panels
Top View-Left Return
U
R
S
Isometric
View
Left Return Left View
- Air Coil Opening
T
C
Power Supply
3/4" [19.1 mm] HV
Knockout
Low Voltage
1/2" [12.7 mm] LV
Knockout
Low Voltage
1/2" [12.7 mm] LV
Knockout
Condensate
3/4" IPT
Front-View
K
1.00 [25.4 mm]
F
J
H
D
L
Air Coil
Field Installed
Discharge Flange
Front
Back
U
R
S
T
C
Back
Front
Right Return Right View
- Air Coil Opening
BSP
CAP
Standard Filter Bracket
ASP
Air Coil
Front
2' [61cm]
Service
Access *
Left Rtn
(Right Rtn
Opposite
Side)
N
B
P
A
O
M
2' [61cm]
Service
3
2
1
E
I
G
Legend
CAP=Control Access Panel
CSP=Compressor Service Panel
BSP=Blower Service Panel
ASP=Alternate Service Panel
Top View-Right Return
Fron
t
P
N
O
Q
Top View-Front Return
P
N
O
Q
CSP
CAP
CSP
CSP
CSP
Air Coil
Air Coil Side
* Note: Shaded areas are recommended service areas, not required.
BSP
Air Coil & Front Side
Air Coil Side
Vertical
Overall Cabinet
Water Connections
Electrical Knockouts
Discharge Connection
Return Connection
Upflow
1
2
Water
J
K
L
using return air opening
Model
A
B
C
D
E
F
G
H
I
IPT
1/2" cond 1/2" cond 3/4" cond
M
N
O
P
Q
R
S
T
U
Width Depth Height
Size
Low
Voltage
Low
Voltage
Power
Supply
Supply
Width
Supply
Depth
Return
Depth
Return
Height
009-012
in.
19.1
19.1
22.0
1.4
2.8
9.4
2.8
6.1
2.3
1/2"
2.9
5.9
8.9
8.9
5.1
9.0
9.0
5.5
2.1
16.2
9.9
0.7
cm.
48.5
48.5
55.9
3.6
7.1
24.0
7.1
15.6
5.9
7.3
14.9
22.5
22.7 12.9
22.9
22.9
14.0
5.3
41.1
25.1
1.9
018
in.
21.5
21.5
39.0
1.8
3.8
15.2
3.6
8.1
2.3
1/2"
4.1
7.1
10.1
6.4
3.8
14.0
14.0
5.3
2.3
18.3
20.2
0.7
cm.
54.6
54.6
99.1
4.5
9.7
38.6
9.1
20.6
5.8
10.5
18.1
25.7
16.1 9.5
35.6
35.6
13.6
5.8
46.5
51.3
1.9
024-030
in.
21.5
21.5
39.0
1.8
3.8
15.2
3.6
8.1
2.3
3/4"
4.1
7.1
10.1
6.4
3.8
14.0
14.0
5.3
2.3
18.3
20.2
0.7
cm.
54.6
54.6
99.1
4.5
9.7
38.6
9.1
20.6
5.8
10.5
18.1
25.7
16.1 9.5
35.6
35.6
13.6
5.8
46.5
51.3
1.9
036 & 042
in.
21.5
26.0
44.0
2.0
3.7
16.2
2.6
10.4
2.3
3/4"
4.1
7.1
10.1
6.4
3.8
14.0
14.0
5.1
2.3
22.8
24.2
0.7
cm.
54.6
66.0
111.8
5.1
9.4
41.1
6.6
26.4
5.8
10.5
18.1
25.7
16.1 9.5
35.6
35.6
13.1
5.8
57.9
61.4
1.9
048-060
in.
24.0
32.5
46.0
1.8
5.9
16.7
2.3
10.1
2.3
1"
4.1
7.1
10.1
6.9
7.3
16.0
18.0
5.1
2.3
29.3
24.2
0.7
cm.
61.0
82.6
116.8
4.5 14.9 42.4
5.8
25.7
5.8
10.5
18.1
25.7
17.4 18.4
40.6
45.7
13.1
5.8
74.4
61.4
1.9
Condensate is 3/4" IPT
Filter bracket extending from unit 2.5" [6.4 cm]. This bracket should be removed when connecting return duct.
Discharge flange field installed
Release
5/13/02
RRB
Added GC006-012
8/25/03
RRB
Fixed water connection on 018
9/5/03
RRB
duct flange installed (
±
0.10 in,
±
2.54mm)
In
Out
3
Condensate
Vertical Upflow Dimensional Data
Notes:
1. Front & Side access is preferred for service access.
. While clear access to all removable panels is not required,
installer should take care to comply with all building codes and
allow adequate clearance for future field service.