5 Starting the system – Procedure
53
The hydraulic system is set and the menu will advance to the next
setting.
11.
Press the
Minus
button if you are not sure.
The menu will return to the hydraulic system selection window.
12.
Select another hydraulic system and proceed as instructed in
The hydraulic system is set and the menu will advance to the next
setting.
B
UFFER
TANK
SENSOR
The message “
Buffer tank sensor: yes?
” appears in the
display.
13.
Use the
Plus
or
Minus
button to select the setting “
Yes
” or “
No
”.
The selected setting will appear in the display.
14.
Confirm using the
arrow
button.
The setting is stored and the menu will advance to the next
setting.
C
ABLE
LENGTH
OF
THE
BUFFER
TANK
SENSOR
The message “
Buffer tank sensor length in [m] 8
”
appears in the display.
15.
Use the
Plus
or
Minus
button to select the actual cable length to
ensure that correct values will be obtained for the temperature
readings.
The corresponding value will appear in the display.
16.
Confirm using the
arrow
button.
The cable length is set and the menu will advance to the next
setting.
M
INIMUM
BUFFER
TANK
TEMPERATURE
The message “
Min. buffer tank TS
min
[°C] 45
” appears
in the display.
17.
Use the
Plus
or
Minus
button to select the desired minimum buffer
tank temperature for load balancing, accumulator or energy store.
The selected minimum buffer tank temperature will appear in the
display.
18.
Confirm using the
arrow
button.
The minimum buffer tank temperature is set and the menu will
advance to the next setting.
M
INIMUM
BOILER
TEMPERATURE
The message “
Min. boiler TK
[°C] 60
” message will appear in the display.
“
Buffer tank sensor in [m] 8
” will only appear if the
“
Buffer tank sensor: yes
” setting was selected.
If the preset minimum temperature is not achieved, the “
Reload
”
indicator is activated and the oil or gas burner is switched on (for
hybrid systems).
The “
minimum boiler temperature
” should not be set to less
than 60 °C.