Electrical connection
38
A4429-3.0
HBM: public
T40FH
8/00 -2/2/2 and appropriate sockets (
). The cable can
be up to 50 m long for voltages
≥
24 V, otherwise it can be up to 20 m long.
If the permissible cable length is exceeded, you can feed the supply voltage in
parallel over two connection cables (connectors 1 and 3). This enables you to
double the permissible length. Alternatively, install an on-site power supply.
Important
The instant you switch on, a current of up to 4 A may flow and this can switch
off power packs with electronic current limiters.
6.6
Supply voltage (Option 3, Code PNJ)
A pre-wired 6-wire transducer connection cable with free ends is available as
an accessory.
Extension cables should be shielded and low capacitance. HBM provides spe
cific cables for this purpose, the 1-KAB0304A-10 (pre-wired) and the
KAB8/00-2/2/2 (by the meter).
The pin assignment can be found in the table in section 6.4.
For the pin assignments at the amplifier end, please refer to the relevant ampli
fier documentation.