![HBM T40FH Mounting Instructions Download Page 60](http://html1.mh-extra.com/html/hbm/t40fh/t40fh_mounting-instructions_2111748060.webp)
= PREFERRED TYPES
Ordering numbers, accessories
58
A4429-3.0
HBM: public
T40FH
14
Ordering numbers, accessories
Ordering number
K-T40FH
[only with Option 2 = MF/ST]
Code
Option 1: Measuring range to
100R
100 kN·m
[only with Option 2 = MF/RO]
130R
130 kN·m
[only with Option 2 = MF/RO]
150R
150 kN·m
[only with Option 2 = MF/RO]
200R
200 kN·m
[only with Option 2 = MF/RO]
250R
250 kN·m
[only with Option 2 = MF/RO]
300R
300 kN·m
[only with Option 2 = MF/RO]
Code
Option 2: Components
MF
Complete measurement flange
RO
Rotor
ST
Stator
N
Not rotating
Code
Option 3: Accuracy
S
Standard (linearity deviation including hysteresis ≤±0.1%)
Code
Option 4: Electrical configuration
[only with Option 2 = MF/ST]
SU2
Out. sign. 10 kHz ±5 kHz and ±10 V, Supp. volt. 18…30 V DC
DU2
Out. sign. 60 kHz ±30 kHz and ±10 V, Supp. volt. 18…30 V DC
HU2
Out. sign. 240 kHz ±120 kHz and ±10 V, Supp. volt. 18…30 V DC
PNJ
mV/V
Code
Option 5: Rotational speed measuring system
0
Without rotational speed measuring system
1
Magnetic rotational speed measuring system
Code
Option 6: Customized modification
S
No customer modification
K-T40FH - 1 0 0 R - M F - S - D U 2 - 0 - S