TEDS transducer identification
T40FH
A4429-3.0
HBM: public
43
Template: Bridge Sensor
Explanation
Required
user
rights
Unit
1)
Parameter
Calibration Period
(Days)
730
days
CAL
Time before recalibra
tion, calculated from the
date specified under Cal
ibration Date.
Measurement
location ID
0
USR
Identification number for
the measuring point.
Can be assigned accord
ing to the application.
Possible values: a num
ber from 0 to 2047. If this
is not enough, the HBM
Channel Comment tem
plate can also be used
for this purpose.
1)
Typical values for an HBM T40FH/150 kN
@
m torque flange
Template: HBM Channel Name
Channel name
T40FH/150 kNm
When creating the
Bridge Sensor
template, the manufacturer defines the physi
cal measured quantity and the physical unit.
The available unit for the particular measured quantity is specified in the IEEE
Standard. For the measured quantity of torque, the unit is "N
@
m".
At the time of creating the template it is also necessary to choose between the
options "Full Precision", "mV/V" and "uV/V" for the accuracy of the characteris
tic transducer curve mapped in TEDS.
The factory setting is "Full Precision", in order to be able to use full digital reso
lution. This choice is also recommended to users who program the TEDS mem
ory themselves.