HB-CL2
Cleaning Unit
Operation
O8305-EN 2022-01
55
Add pre-preservation agent
Proceed as follows if the message
Add agent
is displayed:
1.
Acknowledge horn with the
key.
2.
Fill indicated pre-preservation agent quantity in through the
tank opening in the tank.
WARNING!
Risk of injury due to chemicals!
Chemicals can cause chemical burns, depending
on the type and dilution, cause irritation of the
membrane and respiratory system and be toxic if
swallowed.
Therefore:
– Only allow work on with chemicals s to be
carried out by qualified personnel.
– The general safety instructions on how to
handle chemicals according to the safetydata
sheets must be observed at all times.
– Do not mix chemicals
3.
Acknowledge after adding of pre-preservation agent the query
with the
key.
8.1.2.4 Rinsing phase
In this phase the connected components are being rinsed with
fresh water.
Fig. 28: Setting number of rinses
The rinsing phase is either carried out automatically, omitted or
queried depending on the setting of the number of rinses
parameter.
The number of rinses parameter is set as follows:
1.
Display the menu page
Settings \ Cleaning
.
2.
Set parameter
number of rinses
to the desired value.
With the setting OFF, the rinsing phase is omitted, with the
setting "1 - 9", the rinsing phase is started automatically and
repeated according to the setting. With the setting "query" it is
asked whether another rinsing should be carried out after the
first one or not.