8.3 Functions
8.3.1 Skip current phase
Fig. 34: Turn on skip current phase
The fill (preparation), cleaning operation (cleaning), tool rinsing
(rinsing/preservation) can be skipped before they are over. To do
so, proceed as follows:
1.
Display menu page
Functions
.
2.
Select the parameter
Skip current phase
and press the
key.
The activated function is indicated with the
symbol.
There is a jump from the current phase to the next one if that
is possible.
8.3.2 Tank emptying
Fig. 35: Turn on tank emptying
NOTICE!
Local sewage regulations must be followed.
Information about neutralization can be taken from
the safety sheet or you can ask the manufacturer of
the cleaning agent about it.
Turn on tank emptying as follows:
1.
Display menu page
Functions
.
2.
Select
Emptying tank
and activate it using the
key.
The active function is indicated with the
symbol.
Set dilution factor
Fig. 36: Set dilution factor
If necessary, set the dilution factor prior to turning on Tank
emptying.
1.
Display the menu page
Settings \ Miscellaneous
.
2.
Set
Dilution factor
to the desired value.
NOTICE!
The
Dilution factor
parameter defines the ratio of
fresh water to the current tank contents while the
tank is being emptied. If set at "2", twice as much
fresh water as the current tank contents is added.
If set at "OFF", the tank is emptied without being
diluted.