Cleaning Unit
Operation
O8305-EN 2022-01
51
Cyclical change of the flow
direction
The flow direction is changed cyclical during the cleaning, pre-
preservation, rinsing and preservation phases to obtain a more
efficient cleaning rate.
If necessary, set the desired interval for the change of flow
direction:
1.
Display the menu page
Settings \ Cleaning
.
2.
Set parameter
interval flow inversion
to the desired value.
Mould evacuation
Fig. 22: Time mould evacuation
After finishing of the cleaning, pre-preservation, rinsing and
preservation phases the connected components are being emptied
through the mould evacuation.
Set if necessary the desired maximum cleaning duration:
1.
Display the menu page
Settings \ Miscellaneous
.
2.
Set parameter
Time mould evacuation
to the desired value.
Automatic termination cleaning
If the cleaning rate is stable over the set duration, the unit
automatically stops the cleaning operation.
If necessary, set the desired termination conditions:
1.
Display the menu page
Settings \ Cleaning
.
2.
Set the
Cleaining time aborted
and
Tol band cleaning rate
to
the desired value.
NOTICE!
If the cleaning rate is during the
cleaning time
aborted
within the
Tol. band cleaning rate
, the
cleaning is terminated automatically..