Neutralize medium
Fig. 24: Neutralization warning
Fig. 25: Example of add neutralizing agent
If the warning
Neutralization
is shown, proceed as follows:
1.
Acknowledge horn with the
key.
2.
Place a measuring container under the connection and open
the tap until the measuring container is completely full.
3.
Empty the medium in the measuring container into the tank
through the tank opening.
4.
Place the measuring container back under the test connector
and open the tap until the measuring container is full enough
that the medium can be tested using a test kit.
5.
Test the medium using the test kit and enter the results in
Result pH Value.
6.
Check entry using
Start analysis.
The amount of neutralizing agent is computed automatically
and displayed using the warning
Add agent.
If no
neutralization is needed, the tank contents will be
automatically emptied and the next phase started.
7.
Empty the amount of neutralizing agent into the tank through
the tank opening and acknowledge using the
key.
WARNING!
Danger of being injured by chemicals!
Depending on the type and dilution, chemicals may
cause burns, irritate the respiratory organs and
mucous membranes and be dangerous when
swallowed.
Therefore:
– Only allow work with chemicals to be carried out
by qualified personnel.
– The general safety instructions for handling
chemicals in accordance with the safety data
sheets must be followed carefully.
– Do not mix chemicals
The medium in the tank will now be automatically neutralized.
After the end of the neutralization phase, the warning
Neutralization
is shown again and the medium must be
checked again (repeat all steps).