HB-CL2
Cleaning Unit
Structure and function
30
O8305-EN 2022-01
4.7 Operation modes
4.7.1 Main operating modes
Cleaning
During cleaning, the attached components are rinsed using a
cleaning medium. The flow direction is automatically switched
using the switch valve.
4.7.2 Modes of auxiliary operation
Tank emptying
In the
Tank emptying
mode, the entire contents of the tank are
emptied into the outlet. After the tank has been emptied, the unit
turns off.
Rinse tank
In the
Rinse tank
mode, the tank is automatically filled with fresh
water and emptied through the connection
Rinse tool
In the
Rinse tool
mode, the attached components are rinsed with
fresh water and then emptied.
Tool preservation
In the
Preservation
mode, the attached components are rinsed with
a preservative.
4.8 Work and danger zones
Working areas
The primary working area is located at the front of the unit on
the keyboard.
The secondary working area is located at the rear of the unit.
Danger areas
Connection from unit to consumer is at the rear of the unit.
These areas are not protected by the unit housing. If a hose
ruptures, water treated with chemicals can escape and cause
injuries.