background image

TriStar Variable Speed Pump Control   ____                      ____________________________Page 4 of 16 

WWW.HAYWARDPOOL.COM              USE ONLY HAYWARD GENUINE REPLACEMENT PARTS 

WARNING 

– 

Hazardous Pressure.

  Pool and spa water circulation systems operate under 

hazardous pressure during start­up, normal operation, and after pump shut­off.  Stand clear of circulation 
system equipment during pump start­up.  Failure to follow safety and operation instructions could result in 
violent separation of the pump housing and cover due to pressure in the system, which could cause property 
damage, severe personal injury, or death.  Before servicing pool and spa water circulation system, all 
system and pump controls must be in off position and filter manual air relief valve must be in open 
position.  Before starting system pump, all system valves must be set in a position to allow system water to 

return back to the pool.  Do not change filter control valve position while system pump is running.  Before starting system pump, fully 
open filter manual air relief valve.  Do not close filter manual air relief valve until a steady stream of water (not air or air and water 
mix) is discharged from the valve.  All suction and discharge valves

 MUST

 be

OPEN

 when starting the circulation system.  Failure to 

do so could result in severe personal injury and/or property damage.

 

WARNING 

– 

Separation Hazard.

  Failure to follow safety and operation instructions could 

result in violent separation of pump components.  Strainer cover must be properly secured to pump housing 
with strainer cover lock ring.  Before servicing pool and spa circulation system, all system and pump 
controls must be in off position and filter manual air relief valve must be in open position.  Do not operate 
pool and spa circulation system if a system component is not assembled properly, damaged, or missing.  Do 
not operate pool and spa circulation system unless filter manual air relief valve body is in locked position in 
filter upper body.  All suction and discharge valves

 MUST

 be

OPEN

 when starting the circulation system. 

Failure to do so could result in severe personal injury and/or property damage.

 

WARNING 

 

Never operate or test the circulation system at more than 50 PSI maximum.

 

WARNING 

– 

Fire and burn hazard.

  Motors operate at high temperatures and if they are not properly isolated from 

any flammable structures or foreign debris they can cause fires, which may cause severe personal injury or death.  It is also necessary 
to allow the motor to cool for at least 20 minutes prior to maintenance to minimize the risk for burns.

 

WARNING 

 

Failure to install according to defined instructions may result in severe personal injury or death.

 

General Information 

Introduction

 

This manual contains information for the proper installation and operation of the Hayward TriStar Energy Solution Variable 
Speed Pump Control.  The instructions in this manual

MUST

 be followed precisely.

  Failure to install according to defined 

instructions will void warranty. 

Control Features & Benefits

 

·

 

6 programmable speeds allow you to size the pump to your pool, maximize energy efficiency so you use just enough 
electricity for each specific task, provide greater flexibility for spa and water features, and improve water circulation quality.

 

·

 

Extremely quiet operation, providing flexibility of placement for your equipment pad.

 

·

 

24 hour programmable clock to customize each speed’s length of operation.

 

·

 

Wall mounted enclosure provides easy access.

 

·

 

6 speed interface is easy to program and use, providing superior energy management by defaulting to a “Low Filter” speed to 
filter your pools water.

 

·

 

Easy to use membrane touch­pad.

 

·

 

Illuminated digital display is easy to use at night.

 

·

 

Adapts to Goldline controls for remote operation.

 

·

 

Integrated memory recalls settings.

 

·

 

Comes complete with 9­1/2 ft. of cable and 8 ft. of conduit to connect to the pump.

 

·

 

Temperature and electrical loading protection.

Summary of Contents for TriStar SP322063EEV

Page 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Page 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Page 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Page 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Page 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Page 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Page 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Page 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Page 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Page 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Page 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Page 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Page 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Page 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Page 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Page 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...

Reviews: