Installation Notes

 

1.

  TURN OFF THE ELECTRICAL POWER AT THE CIRCUIT BREAKER.

 

2.  Find a location for the SP3220VSC on a vertical flat surface, out of the direct sunlight, which will not be flooded, and above 

the pump.  This location must be within 8 feet of the pump.  Mount the control enclosure to this location using the provided 
attachment points.  The control must be mounted such that the enclosure vents are free from obstructions and the door may be 
opened without issue.  Do not mount the control enclosure inside a panel or tightly enclosed area, or directly to the side of a 
house. 

3.  Open door and remove panel containing control interface by removing two screws.  Disconnect interface cable from Emerson 

SK drive, and place interface panel in a safe location away from water such that the interface does not make contact with 
anything. 

4.  Connect 230VAC line power supply wiring to terminal block and ground strip as shown.  Spade terminals with up­turned 

lugs must be used to connect wiring to terminal block. 

5.  Connect included phase wiring from control to pump wiring marked #1­3 as shown in wiring diagram below.  Connect green 

ground wire to motor ground screw. 

6.  Connect the control to the pool bonding system using 8AWG (6AWG for Canada) wire.  A lug for bonding is provided on 

the outside/bottom of the enclosure. 

7.  After all electrical connections have been made, reconnect interface cable plug to Emerson SK drive, and replace interface 

panel using two screws. 

8.  Apply power to the system, and proceed to “Installer Initial Setup” on page 7.

 

Wiring Diagram

Summary of Contents for TriStar SP322063EEV

Page 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Page 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Page 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Page 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Page 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Page 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Page 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Page 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Page 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Page 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Page 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Page 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Page 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Page 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Page 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Page 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...

Reviews: