Press 5 (Next) to define the 
Timer­On time.  To change these 
settings, confirm by pressing 6 
(OK).  An underlining cursor will 
appear below hours value.  Press 
5 (Next) or 2 (Prev) to select 
hours or minutes to be set, and 
use Time Up/Dn buttons to select 
desired value.  Press 6 (OK) to 
store this option. 

Press 5 (Next) to define the 
Timer­Off time.  This setting is 
changed the same as above.

 

*TMR.ON      8:00am 

*TMR.ON 

8:00am 

*TMR.ON      8:00am 

*TIMER SAVED! 

*TMR.OFF    5:00pm

 

SETUP mode:

 

PRIME HEIGHT

 

function 

This menu allows the 
user to view the prime 
mode that was 
selected during initial 
setup. 

Press 6 (OK) to display the prime 
mode that was selected during 
initial setup.  After initial setup, 
this becomes a read­only display.

 

*MORE THAN 5 FT

 

(for example) 

SETUP mode:

 

PRESET SETUP

 

function 

This menu allows the 
user to define the 
pump speed and 
duration for each 
preset, which should 
be customized for 
each installation.  Use 
5 (Next) or 2 (Prev) to 
select preset to be 
setup. 

For example, user stops on mode 
4 (Medium High). 

Using % Flow Up/Dn buttons for 
currently displayed mode number 
causes desired pump speed to be 
set within predefined range. 

Using Time Up/Dn buttons for 
currently displayed mode number 
causes desired time to be set 
within predefined range. 

Press 6 (OK) to store preset time 
and % flow settings.  Each preset 
is set the same as above.

 

*SELECT PRESET: 4 

*P4.SPEED=     20% 

*P4.TIME=   1h 30m 

*P4.STORED!

 

SETUP mode:

 

SEQUENCER

 

function 

This menu allows the 
user to define the 
active preset and 
duration for each 
sequence step, which 
should be customized 
for each installation. 
Use 5 (Next) or 2 
(Prev) to select 
sequence step to be 
setup. 

Empty may be 
selected if the user 
does not need all of 
the sequence steps. 
Stop may be selected 
if the user wishes to 
stop the pump during 
peak energy periods or 
another time of day. 

For example, user stops on 
sequence step 1 (S1). 

Use % Flow Up/Dn to select 
desired active preset for displayed 
sequence step, or to select Stop 
Mode or Empty.  If Empty is 
selected, the sequence step will 
be skipped, and the next step will 
be active.  When presets or Stop 
are selected for the sequence step, 
the step time defaults to the time 
set for the displayed preset.  This 
step time may be changed using 
the Time Up/Dn buttons. 

Press 6 (OK) to store sequence 
step settings.  Each sequence step 
is set the same as above.

 

*S1:P1              0h30min 

*S1:P3              1h45min 
*S1:STOP        3h30min 
*S1:EMPTY 

*S1.STORED!

Summary of Contents for TriStar SP322063EEV

Page 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Page 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Page 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Page 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Page 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Page 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Page 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Page 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Page 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Page 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Page 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Page 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Page 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Page 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Page 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Page 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...

Reviews: