TriStar Variable Speed Pump Control ____ ____________________________Page 10 of 16
WWW.HAYWARDPOOL.COM USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
Press 5 (Next) to define the
TimerOn time. To change these
settings, confirm by pressing 6
(OK). An underlining cursor will
appear below hours value. Press
5 (Next) or 2 (Prev) to select
hours or minutes to be set, and
use Time Up/Dn buttons to select
desired value. Press 6 (OK) to
store this option.
Press 5 (Next) to define the
TimerOff time. This setting is
changed the same as above.
*TMR.ON 8:00am
*TMR.ON
8:00am
*TMR.ON 8:00am
*TIMER SAVED!
*TMR.OFF 5:00pm
SETUP mode:
PRIME HEIGHT
function
This menu allows the
user to view the prime
mode that was
selected during initial
setup.
Press 6 (OK) to display the prime
mode that was selected during
initial setup. After initial setup,
this becomes a readonly display.
*MORE THAN 5 FT
(for example)
SETUP mode:
PRESET SETUP
function
This menu allows the
user to define the
pump speed and
duration for each
preset, which should
be customized for
each installation. Use
5 (Next) or 2 (Prev) to
select preset to be
setup.
For example, user stops on mode
4 (Medium High).
Using % Flow Up/Dn buttons for
currently displayed mode number
causes desired pump speed to be
set within predefined range.
Using Time Up/Dn buttons for
currently displayed mode number
causes desired time to be set
within predefined range.
Press 6 (OK) to store preset time
and % flow settings. Each preset
is set the same as above.
*SELECT PRESET: 4
*P4.SPEED= 20%
*P4.TIME= 1h 30m
*P4.STORED!
SETUP mode:
SEQUENCER
function
This menu allows the
user to define the
active preset and
duration for each
sequence step, which
should be customized
for each installation.
Use 5 (Next) or 2
(Prev) to select
sequence step to be
setup.
Empty may be
selected if the user
does not need all of
the sequence steps.
Stop may be selected
if the user wishes to
stop the pump during
peak energy periods or
another time of day.
For example, user stops on
sequence step 1 (S1).
Use % Flow Up/Dn to select
desired active preset for displayed
sequence step, or to select Stop
Mode or Empty. If Empty is
selected, the sequence step will
be skipped, and the next step will
be active. When presets or Stop
are selected for the sequence step,
the step time defaults to the time
set for the displayed preset. This
step time may be changed using
the Time Up/Dn buttons.
Press 6 (OK) to store sequence
step settings. Each sequence step
is set the same as above.
*S1:P1 0h30min
*S1:P3 1h45min
*S1:STOP 3h30min
*S1:EMPTY
*S1.STORED!