VARIABLE SPEED INTERFACE ­ BASIC OPERATION NOTES:

 

)

  Timer Enabled (recommended):

  When the timer is enabled, the pump will be stopped when the control first receives power, 

until the Timer­ON time is reached, at which time it will prime and proceed through the steps defined in the Sequencer menu.  The 
pump will stop when the system reaches the Timer­OFF time.  The pump may be manually stopped by pressing the 5 and 6 buttons 
simultaneously for more than 5 seconds.  Pressing any preset button after manually stopping the pump will cause the pump to prime 
and operate according to the preset chosen.

 

Timer Disabled:

  When the timer is disabled, the pump will prime when the control first receives power, and will then default to P2 

(Low Filter).  It will continue to run according to P2 until power is disconnected from the control.  After the pump has primed, the % 
Flow and Time Up/Dn buttons, as well as the 1­6 buttons, are active.  Pressing any of the 1­6 buttons will cause the pump to run 
temporarily according to the set flow and time for the chosen preset.  The % Flow and Time Up/Dn buttons may be used to 
temporarily modify the set flow and time for the chosen preset.  After the chosen preset expires, the pump will default back to P2.  The 
pump may be manually stopped by pressing the 5 and 6 buttons simultaneously for more than 5 seconds.  After the pump is stopped, it 
may be restarted by pressing the 5 and 6 buttons simultaneously again for more than 5 seconds, at which point the pump will prime 
and then default to P2 (Low Filter). 

)  RTC – Real Time Clock 

)  Factory defaults are as follows.  User/installer may note custom presets in the spaces provided. 

)  If the sequencer is used, user/installer may note custom sequencer settings in the spaces provided.

 

Sequence 

Step 

Preset 

Used 

Duration 

Time Start

 

Timer On 

N/A 

N/A 

S1
S2
S3
S4
S5
S6
S7
S8 

Timer Off 

N/A 

N/A

 

Factory Presets 

Custom Presets 

Mode  Name 

% Flow 

Time 

% Flow 

Time

 

PRIME 

5 FEET OR LESS 
MORE THAN 5 FEET 

65
85 

6 min 
8 min 

P1 

Low 

50 

30 min 

P2 

Low Filter 

50 

30 min 

P3 

Medium Low 

50 

30 min 

P4 

Medium High 

50 

30 min 

P5 

High Filter Cleaner 

50 

30 min 

P6 

Maximum Flow 

50 

30 min

Summary of Contents for TriStar SP322063EEV

Page 1: ...efficient dependable corrosion free service The advanced design provides superior performance while reducing maintenance requirements NOTE To prevent potential injury and to avoid unnecessary service...

Page 2: ...g such that it cannot be readily disassembled for storage A storable pool is constructed so that it is capable of being readily disassembled for storage and reassembled to its original integrity Thoug...

Page 3: ...ielectricite premiere partie brancher uniquement a une derivation protegee par un disjoncteur differentiel de classe A WARNING Suction Entrapment Hazard Suction in suction outlets and or suction outle...

Page 4: ...and spa circulation system unless filter manual air relief valve body is in locked position in filter upper body All suction and discharge valves MUST be OPEN when starting the circulation system Fai...

Page 5: ...l and motor Use green ground terminal provided under motor canopy or access place use size and type wire required by code Connect control and motor ground terminals to control enclosure ground Bond co...

Page 6: ...e panel containing control interface by removing two screws Disconnect interface cable from Emerson SK drive and place interface panel in a safe location away from water such that the interface does n...

Page 7: ...me Up Dn buttons to change the selected value selected value will be displayed with underlining cursor Press 6 OK to store current settings CHECK THE CLOCK SET Mon 12 50pm Clock setting is complete Pr...

Page 8: ...st make these selections before the system will allow the pump to operate If a mistake is made during the initial setup the user may override the incorrect setup by disconnecting power to the system a...

Page 9: ...P HARDWARE SETUP CONTROL SETUP SETUP mode continued as above Press 6 OK to enter selected menu option for example LANGUAGE SETUP Press 1 Exit to exit the menu LANGUAGE SETUP ENGLISH SETUP mode LANGUAG...

Page 10: ...buttons for currently displayed mode number causes desired pump speed to be set within predefined range Using Time Up Dn buttons for currently displayed mode number causes desired time to be set with...

Page 11: ...the Flow Up Dn buttons may temporarily change for each preset Use 5 Next or 2 Prev to select preset range to be setup For example user stops on preset 6 Maximum Flow Press Flow Up Dn buttons to displa...

Page 12: ...d during Prime Mode 8 min REMAINS PRIME P4 PUMP SPEED 85 End of prime Operate according to active mode with flow set for this mode and for preset time After Prime Mode is completed the pump will opera...

Page 13: ...from the control After the pump has primed the Flow and Time Up Dn buttons as well as the 1 6 buttons are active Pressing any of the 1 6 buttons will cause the pump to run temporarily according to the...

Page 14: ...ons and terminals are properly attached and connected E6 VFD EEPROM ER indicates that internal Emerson EEPROM memory is corrupted In such case the Emerson drive will not hold its predefined configurat...

Page 15: ...Y HAYWARD GENUINE REPLACEMENT PARTS PRODUCT REGISTRATION Retain For Your Records DATE OF INSTALLATION ____________________ INITIAL PRESSURE GAUGE READING CLEAN FILTER _______________________ PUMP MODE...

Page 16: ...be returned transportation paid to the place of purchase or to the nearest authorized Hayward service center For further Hayward dealer or service center information contact Hayward customer service d...

Reviews: