Page 2-9
Pilot’s Operating Manual
Revision A2: Nov, 2004
Sub-section 2
GROUND SERVICING
Hawker 800XP Pro Line 21
Section VI - GROUND OPERATIONS
THRUST REVERSERS
WARNING:
MAKE SURE THE THRUST REVERSER SYSTEM IS DISABLED BEFORE ANY
WORK IS COMPLETED ON THE SYSTEM OR ANY OTHER SYSTEM WHICH IS
OPERATED BY ELECTRICAL AND/OR HYDRAULIC POWER.
THIS IS ESPECIALLY IMPORTANT WHEN WORKING NEAR THE THRUST
REVERSER DOORS.
MAKE SURE ALL OF THE FOLLOWING PRECAUTIONS ARE COMPLETED
BEFORE STARTING ANY MAINTENANCE WORK:
1. Make sure the electrical power is off.
2. Pin the thrust reverser doors in the stowed or deployed position (Figure 4).
3. Open the stow and deploy circuit breakers for No. 1 and No. 2 thrust reversers.
4. Disconnect the electrical connectors from both control selector valves located below the hydraulic
box in the rear equipment bay.
STOWED POSITION
DEPLOYED POSITION
Figure 4
Thrust Reverser Pins