Page 2-30
Pilot’s Operating Manual
Revision A2: Nov, 2004
Sub-section 2
GROUND SERVICING
Hawker 800XP Pro Line 21
Section VI - GROUND OPERATIONS
Gravity Refueling Wing Tanks Procedure (continued)
(8) Remove the refuel nozzle, install and lock the filler cap, disconnect nozzle bonding
lead.
(a) Engage the cap into the skin adapter with the arrow on the cap pointed forward.
(b) Turn the handle to lock and the seal cap.
(c) Lower the handle into the recess.
(9) Disconnect the refuel vehicle or hydrant bonding lead.
(10) Remove the wing skin protection mat from the wing.
CAUTION: INVESTIGATE ANY CONTAMINATION, OTHER THAN WATER, OF THE FOLLOWING
DRAINED SAMPLE.
(11) Drain all water from the tanks (Figures 6 & 8).
(12) If the POWER switch on the refuel control panel was selected to ON, select the
POWER switch to OFF.
(13) Check the overhead roof panel REFUEL ON annunciator is extinguished.
(14) If necessary, de-energize DC busbars.