Page 12-6
Pilot’s Operating Manual
Original Issue: Feb, 2002
Sub-section 12
OXYGEN SYSTEM
Hawker 800XP Pro Line 21
Section III - SYSTEMS DESCRIPTION
OPERATION
Oxygen from the storage cylinders is fed to the master SUPPLY valve on the flight compartment oxygen
panel on the left console.
Opening the master SUPPLY valve allows oxygen to flow to the contents indicator and the pressure
regulator, then, at 70 psi to the combined mask-regulators, therapeutic outlets and the baromatic valve.
Figure 4
Flight Compartment Oxygen Panel on Left Console
TEST
PASSENGER SUPPLY
EMERGENCY
PU
L L
PULL TO OPERATE
PUSH FOR OFF
SUPPLY
ON
EMPTY
1/4
1/2
3/4
FULL
OXYGEN
CONTENTS
OXYGEN