92
4000562980
E 07.16
USA / GB
Mast
Clearance procedure
MS0061
4 - Procedure
Wedging of the folded mast must be carried out with a functional clearance of 1 mm in the left/right axis and 0,5 mm
in the front/rear axis.
If the mast jams when being extended, increase the clearance.
If the distribution of the wedges cannot be equivalent on each side of a tube, wedge the right and rear sides more
according to the red dots on the diagram below.
The maximum wedging authorised per pad is 2 mm.
The pads must be attached with pre-coated CHC M6x20 screws and M6 contact washers.
Avant /
Front
Arrière /
Rear
Gauche /
Left
Droite /
Right