3. INSTALLATION OF PLUMBING
A. INTAKE
Screw the 003-
EL3412 (3/4” to ½”elbow) into the bottom of the tank. Second screw the
002-
2212(½” ball valve) with elbow into the filter assembly. Lastly, route the 002-9001(1/2”
hose) from bottom of the tank to ball valve. Secure with hose clamps.
B. OUTLET ROUND BALER
Run hose from the pump outlet to the gauge. The gauge is assembled with two straight
fittings; an elbow is supplied in the parts bag to be used if necessary. From the gauge the
hose will need to be run to the first nozzle tube with the check valve. On John Deere 8
series and Agco balers the hose from the gauge will go the check valve on the spray shield.
Cut the hose to length and attach the female disconnect and straight fitting. Attach these to
the check valve using one washer.
ROUND BALER
TANK
FILTER BOWL
ASSEMBLY
GAUGE
FEMALE
DISCONNECT
CHECK
VALVE
NOZZLE
TUBE