11 

 

GENERAL CALIBRATION CHART IN POUNDS PER HOUR 

Use the following chart for all applications that require pounds measurements. 

 

         

POUNDS PER HOUR WITH THREE NOZZLES 

 

 

 

 

 

 

INCLUDED IN KIT 

 

 

 

 

 

 

YELLOW  

 

RED  

 

GREEN  

 

BLUE  

  BLACK    

 

 

 

 

650067 

 

XR11001 

  XR110015    XR11002    XR11004    CENTER   

 

 

650033 

 

650050 

 

6501 

 

6502 

 

6503 

  OUTSIDE  

  PSI   

   

   

   

   

   

 

  15 

53 

 

64 

 

112 

 

192 

 

320 

 

 

 

  20 

63 

 

76 

 

133 

 

228 

 

380 

 

 

 

  25 

70 

 

84 

 

147 

 

252 

 

420 

 

 

 

  30 

77 

 

92 

 

161 

 

276 

 

460 

 

 

 

  35 

84 

 

100 

 

175 

 

300 

 

N/A 

 

 

 

  40 

89 

 

106 

 

186 

 

318 

 

N/A 

 

 

 

  45 

94 

 

112 

 

196 

 

336 

 

N/A 

 

 

 

  50 

97 

 

116 

 

203 

 

348 

 

N/A 

 

 

 

  55 

102 

 

122 

 

214 

 

366 

 

N/A 

 

 

 

  60 

107 

 

128 

 

224 

 

384 

 

N/A 

 

 

 

 

GENERAL CALIBRATION CHART IN GALLONS PER HOUR 

Use the following chart for all applications that require volume measurements. 

 

         

GALLONS PER HOUR WITH THREE NOZZLES 

 

 

 

 

 

 

INCLUDED IN KIT 

 

 

 

 

 

 

YELLOW  

 

RED  

 

GREEN  

 

BLUE  

  BLACK    

 

 

 

 

650067 

 

XR11001 

  XR110015    XR11002    XR11004    CENTER   

 

 

650033 

 

650050 

 

6501 

 

6502 

 

6503 

  OUTSIDE  

  PSI   

   

   

   

   

   

 

  15 

5.2 

 

7.3 

 

12.9 

 

22.0 

 

31.9 

 

 

 

  20 

5.6 

 

8.4 

 

15.1 

 

24.1 

 

42.2 

 

 

 

  25 

6.3 

 

9.5 

 

16.7 

 

28.3 

 

47.3 

 

 

 

  30 

7.0 

 

10.6 

 

18.6 

 

31.0 

 

52.2 

 

 

 

  35 

7.5 

 

11.3 

 

19.7 

 

33.5 

 

N/A 

 

 

 

  40 

8.0 

 

12.0 

 

21.0 

 

36.0 

 

N/A 

 

 

 

  45 

8.4 

 

12.6 

 

22.3 

 

38.3 

 

N/A 

 

 

 

  50 

8.9 

 

13.2 

 

23.6 

 

40.7 

 

N/A 

 

 

 

  55 

9.3 

 

13.8 

 

24.5 

 

42.5 

 

N/A 

 

 

 

  60 

9.7 

 

14.4 

 

25.6 

 

44.4 

 

N/A 

 

 

 

 

 
 

 

Summary of Contents for 442U

Page 1: ...010 0442U Revised 6 22 OWNER S MANUAL Model 442U 25 Gallon Preservative Applicators Forage Harvester...

Page 2: ...APPLYING RATE DECAL 8 LOCATION OF CONTROL BOX 8 WIRING 8 OPERATING INSTRUCTIONS 8 MESSAGE LIGHT 8 OPERATION 8 11 CALIBRATION 9 11 DETERMINING TONS PER HOUR 9 DETERMINING RATE OF CHEMICAL 10 SELECTING...

Page 3: ...odel 442U applicator If something goes wrong bring this manual into the dealer so they can order the correct parts for you Ordering the correct part number is very important It will save you time mone...

Page 4: ...r side if necessary Take care to check behind the area before drilling The bracket will be secured on each side with three 1 2 x 1 1 4 hex bolts six flat washers three lock washers and three hex nuts...

Page 5: ...ll connect to the tank at point B Thread 3 4 elbow fitting 003 EL3434 into end of tank Run 3 4 hose from the elbow down the frame to the bottom of the baler Drill 1 4 holes to accept the valve holder...

Page 6: ...fitting CENTER Use 2 way fitting RIGHT SIDE Use 2 way fitting 48 12 from left Center 12 from right 60 14 from left Center 14 from right 72 15 from left Center 15 from right Aim the nozzle pipes up so...

Page 7: ...gauge The gauge is assembled with two straight fittings an elbow is supplied in the parts bag to be used if necessary From the gauge the hose will need to be run to the first nozzle tube with the che...

Page 8: ...e tank with 5 gallons of water With control box connected to the applicator and the power cord hooked to the 12 volt battery we can start the test First flip on the toggle switch You might hear the bu...

Page 9: ...eference 2 minutes with 1000lb and you will come up with 15 ton per hour Average time to make a bale min Round Baler Tons per Hour Weight per Baler 600 800 1000 1200 1400 1600 1800 2000 2200 0 5 36 0...

Page 10: ...g at you can select your tips and determine your gauge settings 1 Multiply the tons per hour by the amount of chemical required for the moisture you are applying at This sum will give you the applicat...

Page 11: ...96 336 N A 50 97 116 203 348 N A 55 102 122 214 366 N A 60 107 128 224 384 N A GENERAL CALIBRATION CHART IN GALLONS PER HOUR Use the following chart for all applications that require volume measuremen...

Page 12: ...g kit 007 4581 6 If you are using bacterial inoculants flush out system daily after each use 7 Clean tank cap breather every 20 hrs or more frequently if required 8 WARNING Do not climb on baler for m...

Page 13: ...ter bowl assembly 2 Electronic box out of adjustment 2 Refer to box adjustment page 3 Pump worn or dirty 3 Rebuild pump 4 Low supply voltage Pump requires 12v minimum 4 Check voltage at connection wit...

Page 14: ...Ref Description Part Qty Ref Description Part Qty 1 Pump 007 4120S 1 8 Ball valve 002 2212 1 2 Elbow fitting 003 EL3812 1 9 Elbow fitting 003 EL1212 1 3 Street elbow 003 SE38 1 10 Gauge 002 2208Z 1 4...

Page 15: ...1 Tip Kit Complete 030 9002 1 2 Straight fitting 003 A1412 5 Tip Kit Includes 3 Tee 003 TT14 3 Plastic Box 008 9000 1 4 Check valve 004 1207V 1 Red Cap 004 1207B 3 5 Female coupler 004 1207G 3 Outsid...

Page 16: ...16 NOTES...

Page 17: ...ansportation charges prepaid This warranty shall not be interpreted to render Harvest Tec LLC liable for injury or damages of any kind direct consequential or contingent to persons or property Further...

Page 18: ...18 HARVEST TEC LLC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...

Reviews: