6
2. INSTALLATION OF SPRAY NOZZLE ASSEMBLY
The cross bar on the wind guard above the pick-up head provides a mounting point for the nozzle
pipes. Space the nozzles by the chart below:
PICK-UP HEAD
WIDTH
LEFT SIDE
(Use plugged fitting)
CENTER
(Use 2-way fitting)
RIGHT SIDE
(Use 2-way fitting)
48”
12” from left
Center
12” from right
60”
14” from left
Center
14” from right
72”
15” from left
Center
15” from right
Aim the nozzle pipes up so that the tips spray in a generally horizontal direction. The tips should be pointed
toward the starter rolls of the baler. The tips should be located so they will be somewhere between 14” and
18
” form the normal path of hay.