background image

 
 

INSTALLATION OF TANK, MOUNTING BRACKETS, GAUGE, & DRAIN/FILL LINE CONT. 
 

Mount the tank on the tank base bracket (001-442U) as shown below and on the previous page.  The 
position the tank and saddle so that the additional side hole on the tank will be facing the front of the 
ba

ler.  The tank saddle will have four holes that will line up with point A.  Use four 1/2” x 1 – 1/4” hex 

bolts, four flat washers, and four lock washers to secure the tank to points A.    
 
The drain/fill line will connect to the tank at point B.  Thread 3/4" elbow fitting (#003-EL3434) into end 
of tank.  

  

Run 3/4" hose from the elbow down the frame to the bottom of the baler.  Drill 1/4" holes to 

accept the valve holder bracket and use 5/16” x11/4” self-tapping screws. Connect valve assembly to 
other end of hose.  Place hose clamps on both ends.  

The drain/fill line needs to be used for all 

filling or draining of the tank.  Fill or drain from ground level only.  Failure to do so can lead to 
injury. 
 

Locate gauge assembly.  On round balers the gauge can be mounted to front of tank saddle or in any 
other location that is easily viewed from the tractors seat.   

 

        

 

 

Valve 

bracket 

and quick 

coupler 

Summary of Contents for 442U

Page 1: ...010 0442U Revised 6 22 OWNER S MANUAL Model 442U 25 Gallon Preservative Applicators Forage Harvester...

Page 2: ...APPLYING RATE DECAL 8 LOCATION OF CONTROL BOX 8 WIRING 8 OPERATING INSTRUCTIONS 8 MESSAGE LIGHT 8 OPERATION 8 11 CALIBRATION 9 11 DETERMINING TONS PER HOUR 9 DETERMINING RATE OF CHEMICAL 10 SELECTING...

Page 3: ...odel 442U applicator If something goes wrong bring this manual into the dealer so they can order the correct parts for you Ordering the correct part number is very important It will save you time mone...

Page 4: ...r side if necessary Take care to check behind the area before drilling The bracket will be secured on each side with three 1 2 x 1 1 4 hex bolts six flat washers three lock washers and three hex nuts...

Page 5: ...ll connect to the tank at point B Thread 3 4 elbow fitting 003 EL3434 into end of tank Run 3 4 hose from the elbow down the frame to the bottom of the baler Drill 1 4 holes to accept the valve holder...

Page 6: ...fitting CENTER Use 2 way fitting RIGHT SIDE Use 2 way fitting 48 12 from left Center 12 from right 60 14 from left Center 14 from right 72 15 from left Center 15 from right Aim the nozzle pipes up so...

Page 7: ...gauge The gauge is assembled with two straight fittings an elbow is supplied in the parts bag to be used if necessary From the gauge the hose will need to be run to the first nozzle tube with the che...

Page 8: ...e tank with 5 gallons of water With control box connected to the applicator and the power cord hooked to the 12 volt battery we can start the test First flip on the toggle switch You might hear the bu...

Page 9: ...eference 2 minutes with 1000lb and you will come up with 15 ton per hour Average time to make a bale min Round Baler Tons per Hour Weight per Baler 600 800 1000 1200 1400 1600 1800 2000 2200 0 5 36 0...

Page 10: ...g at you can select your tips and determine your gauge settings 1 Multiply the tons per hour by the amount of chemical required for the moisture you are applying at This sum will give you the applicat...

Page 11: ...96 336 N A 50 97 116 203 348 N A 55 102 122 214 366 N A 60 107 128 224 384 N A GENERAL CALIBRATION CHART IN GALLONS PER HOUR Use the following chart for all applications that require volume measuremen...

Page 12: ...g kit 007 4581 6 If you are using bacterial inoculants flush out system daily after each use 7 Clean tank cap breather every 20 hrs or more frequently if required 8 WARNING Do not climb on baler for m...

Page 13: ...ter bowl assembly 2 Electronic box out of adjustment 2 Refer to box adjustment page 3 Pump worn or dirty 3 Rebuild pump 4 Low supply voltage Pump requires 12v minimum 4 Check voltage at connection wit...

Page 14: ...Ref Description Part Qty Ref Description Part Qty 1 Pump 007 4120S 1 8 Ball valve 002 2212 1 2 Elbow fitting 003 EL3812 1 9 Elbow fitting 003 EL1212 1 3 Street elbow 003 SE38 1 10 Gauge 002 2208Z 1 4...

Page 15: ...1 Tip Kit Complete 030 9002 1 2 Straight fitting 003 A1412 5 Tip Kit Includes 3 Tee 003 TT14 3 Plastic Box 008 9000 1 4 Check valve 004 1207V 1 Red Cap 004 1207B 3 5 Female coupler 004 1207G 3 Outsid...

Page 16: ...16 NOTES...

Page 17: ...ansportation charges prepaid This warranty shall not be interpreted to render Harvest Tec LLC liable for injury or damages of any kind direct consequential or contingent to persons or property Further...

Page 18: ...18 HARVEST TEC LLC P O BOX 63 2821 HARVEY STREET HUDSON WI 54016 PHONE 715 386 9100 1 800 635 7468 FAX 715 381 1792 Email info harvesttec com...